This page is part of the FUT Infrastructure (v3.3.0: Release) based on FHIR (HL7® FHIR® Standard) R4. This is the current published version in its permanent home (it will always be available at this URL). For a full list of available versions, see the Directory of published versions
Active as of 2024-11-05 |
@prefix fhir: <http://hl7.org/fhir/> .
@prefix owl: <http://www.w3.org/2002/07/owl#> .
@prefix rdfs: <http://www.w3.org/2000/01/rdf-schema#> .
@prefix xsd: <http://www.w3.org/2001/XMLSchema#> .
# - resource -------------------------------------------------------------------
a fhir:OperationDefinition ;
fhir:nodeRole fhir:treeRoot ;
fhir:id [ fhir:v "-s-execute-patient-devices"] ; #
fhir:text [
fhir:status [ fhir:v "generated" ] ;
fhir:div "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p class=\"res-header-id\"><b>Generated Narrative: OperationDefinition -s-execute-patient-devices</b></p><a name=\"-s-execute-patient-devices\"> </a><a name=\"hc-s-execute-patient-devices\"> </a><a name=\"-s-execute-patient-devices-da-DK\"> </a><p>URL: [base]/$execute-patient-devices</p><h3>Parameters</h3><table class=\"grid\"><tr><td><b>Use</b></td><td><b>Name</b></td><td><b>Scope</b></td><td><b>Cardinality</b></td><td><b>Type</b></td><td><b>Binding</b></td><td><b>Documentation</b></td></tr><tr><td>IN</td><td>anonymization</td><td/><td>1..1</td><td><a href=\"http://hl7.org/fhir/R4/datatypes.html#string\">string</a></td><td/><td/></tr><tr><td>IN</td><td>organization</td><td/><td>0..1</td><td><a href=\"http://hl7.org/fhir/R4/references.html#Reference\">Reference</a></td><td/><td/></tr><tr><td>IN</td><td>period</td><td/><td>0..1</td><td><a href=\"http://hl7.org/fhir/R4/datatypes.html#Period\">Period</a></td><td/><td/></tr><tr><td>IN</td><td>devicetype</td><td/><td>0..1</td><td><a href=\"http://hl7.org/fhir/R4/datatypes.html#Coding\">Coding</a></td><td/><td/></tr><tr><td>OUT</td><td>return</td><td/><td>0..1</td><td><a href=\"http://hl7.org/fhir/R4/binary.html\">Binary</a></td><td/><td/></tr></table></div>"
] ; #
fhir:url [ fhir:v "https://reporting.devtest.systematic-ehealth.com/fhir/OperationDefinition/-s-execute-patient-devices"^^xsd:anyURI] ; #
fhir:version [ fhir:v "3.3.0"] ; #
fhir:name [ fhir:v "execute-patient-devices"] ; #
fhir:title [ fhir:v "Execute patient devices"] ; #
fhir:status [ fhir:v "active"] ; #
fhir:kind [ fhir:v "operation"] ; #
fhir:date [ fhir:v "2024-11-05T10:04:41+00:00"^^xsd:dateTime] ; #
fhir:publisher [ fhir:v "Den telemedicinske infrastruktur (eHealth Infrastructure)"] ; #
fhir:contact ( [
fhir:name [ fhir:v "Den telemedicinske infrastruktur (eHealth Infrastructure)" ] ;
( fhir:telecom [
fhir:system [ fhir:v "url" ] ;
fhir:value [ fhir:v "http://ehealth.sundhed.dk" ] ] )
] ) ; #
fhir:description [ fhir:v "### Report Contents\nThis report contains Device information for each EpisodeOfCare:\n- Device\n- DeviceUseStatement\n- DeviceMetrics\n### Grouping \nThis report is grouped by EpsiodeOfCare. Each group is returned in a separate JSon file.\n### Parameters\n- organization: Filter on EpisodeOfCare.managingOrganization match\n- period: Filter on DeviceUseStatement.whenUsed overlap\n### Output\nOutput can be found in Binary.content. This is a Base64 encoded .zip file containing JSon files corresponding to the report groups.\n### Example output\nAll returned objects are Fhir resources. See the implementation guide for details\n\n {\n 'EHealthEpisodeOfCare': {\n 'resourceType': 'EpisodeOfCare',\n 'id': 'F417C17F9FDE24C9090BD629C8EE1697',\n 'meta': {\n 'versionId': '1',\n 'profile': ['http://ehealth.sundhed.dk/fhir/StructureDefinition/ehealth-episodeofcare']\n },\n 'extension': [{\n 'url': 'http://ehealth.sundhed.dk/fhir/StructureDefinition/ehealth-episodeofcare-caremanagerOrganization',\n 'valueReference': {\n 'reference': 'https://organization.local.ehealth.sundhed.dk/fhir/Organization/313D8B0E0AC8EA8169D1DA45ECEEACB9'\n }\n }\n ],\n 'status': 'active',\n 'diagnosis': [{\n 'condition': {\n 'reference': 'https://careplan.local.ehealth.sundhed.dk/fhir/Condition/9A7FCD55CA3031585A8F1690DB1D8034'\n },\n 'rank': 1\n }\n ],\n 'patient': {\n 'reference': 'https://patient.local.ehealth.sundhed.dk/fhir/Patient/A1D94F323D8EF09E5D913D9522FD83C4'\n },\n 'managingOrganization': {\n 'reference': 'https://organization.local.ehealth.sundhed.dk/fhir/Organization/8DC75F2B12BCC832F92CC065C3D0B451'\n },\n 'period': {\n 'start': '1970-01-01T01:00:01+01:00',\n 'end': '1970-01-01T01:01:40+01:00'\n }\n },\n 'EHealthDeviceUseStatement': [{\n 'resourceType': 'DeviceUseStatement',\n 'id': '9541E8EAEAD24376F208D5CD8A4D25F5',\n 'meta': {\n 'versionId': '1',\n 'profile': ['http://ehealth.sundhed.dk/fhir/StructureDefinition/ehealth-deviceusestatement']\n },\n 'extension': [{\n 'url': 'http://ehealth.sundhed.dk/fhir/StructureDefinition/ehealth-deviceusestatement-context',\n 'valueReference': {\n 'reference': 'https://careplan.local.ehealth.sundhed.dk/fhir/CarePlan/23D34B29DD02EB232B6575537FE8ADC5'\n }\n }\n ],\n 'status': 'active',\n 'subject': {\n 'reference': 'https://patient.local.ehealth.sundhed.dk/fhir/Patient/AC38B1F6391F256002E5A7BE69CB2586'\n },\n 'device': {\n 'reference': 'https://device.local.ehealth.sundhed.dk/fhir/Device/08D51B81A7FE5B480278150A94D4048A'\n }\n }\n ],\n 'EHealthDevice': [{\n 'resourceType': 'Device',\n 'id': '08D51B81A7FE5B480278150A94D4048A',\n 'meta': {\n 'versionId': '1',\n 'profile': ['http://ehealth.sundhed.dk/fhir/StructureDefinition/ehealth-device']\n },\n 'extension': [{\n 'url': 'http://ehealth.sundhed.dk/fhir/StructureDefinition/ehealth-device-privatelyOwned',\n 'valueBoolean': true\n }\n ],\n 'status': 'active'\n }\n ],\n 'EHealthDeviceMetric': [{\n 'resourceType': 'DeviceMetric',\n 'id': '7EA21ACD27EE012439F1440574A6BB21',\n 'meta': {\n 'versionId': '1',\n 'profile': ['http://ehealth.sundhed.dk/fhir/StructureDefinition/ehealth-devicemetric']\n },\n 'extension': [{\n 'url': 'http://ehealth.sundhed.dk/fhir/StructureDefinition/ehealth-devicemetric-qualities',\n 'extension': [{\n 'url': 'category',\n 'valueCodeableConcept': {\n 'coding': [{\n 'system': 'http://ehealth.sundhed.dk/cs/devicemetric-quality-types',\n 'code': 'initial'\n }\n ]\n }\n }, {\n 'url': 'value',\n 'valueInteger': 5\n }\n ]\n }, {\n 'url': 'http://ehealth.sundhed.dk/fhir/StructureDefinition/ehealth-devicemetric-templateQualities',\n 'extension': [{\n 'url': 'category',\n 'valueCodeableConcept': {\n 'coding': [{\n 'system': 'http://ehealth.sundhed.dk/cs/devicemetric-quality-types',\n 'code': 'initial'\n }\n ]\n }\n }, {\n 'url': 'value',\n 'valueInteger': 10\n }\n ]\n }, {\n 'url': 'http://ehealth.sundhed.dk/fhir/StructureDefinition/ehealth-devicemetric-templateQualities',\n 'extension': [{\n 'url': 'category',\n 'valueCodeableConcept': {\n 'coding': [{\n 'system': 'http://ehealth.sundhed.dk/cs/devicemetric-quality-types',\n 'code': 'initial'\n }\n ]\n }\n }, {\n 'url': 'value',\n 'valueInteger': 12\n }\n ]\n }, {\n 'url': 'http://ehealth.sundhed.dk/fhir/StructureDefinition/ehealth-devicemetric-templateQualities',\n 'extension': [{\n 'url': 'category',\n 'valueCodeableConcept': {\n 'coding': [{\n 'system': 'http://ehealth.sundhed.dk/cs/devicemetric-quality-types',\n 'code': 'initial'\n }\n ]\n }\n }, {\n 'url': 'value',\n 'valueInteger': 14\n }\n ]\n }\n ],\n 'identifier': {\n 'value': 'Foo'\n },\n 'type': {\n 'text': 'code'\n },\n 'source': {\n 'reference': 'https://device.local.ehealth.sundhed.dk/fhir/Device/08D51B81A7FE5B480278150A94D4048A'\n },\n 'category': 'calculation'\n }\n ]\n }\n"] ; #
fhir:jurisdiction ( [
( fhir:coding [
fhir:system [ fhir:v "urn:iso:std:iso:3166"^^xsd:anyURI ] ;
fhir:code [ fhir:v "DK" ] ;
fhir:display [ fhir:v "Denmark" ] ] )
] ) ; #
fhir:affectsState [ fhir:v "true"^^xsd:boolean] ; #
fhir:code [ fhir:v "execute-patient-devices"] ; #
fhir:system [ fhir:v "true"^^xsd:boolean] ; #
fhir:type [ fhir:v "false"^^xsd:boolean] ; #
fhir:instance [ fhir:v "false"^^xsd:boolean] ; #
fhir:parameter ( [
fhir:name [ fhir:v "anonymization" ] ;
fhir:use [ fhir:v "in" ] ;
fhir:min [ fhir:v "1"^^xsd:integer ] ;
fhir:max [ fhir:v "1" ] ;
fhir:type [ fhir:v "string" ]
] [
fhir:name [ fhir:v "organization" ] ;
fhir:use [ fhir:v "in" ] ;
fhir:min [ fhir:v "0"^^xsd:integer ] ;
fhir:max [ fhir:v "1" ] ;
fhir:type [ fhir:v "Reference" ]
] [
fhir:name [ fhir:v "period" ] ;
fhir:use [ fhir:v "in" ] ;
fhir:min [ fhir:v "0"^^xsd:integer ] ;
fhir:max [ fhir:v "1" ] ;
fhir:type [ fhir:v "Period" ]
] [
fhir:name [ fhir:v "devicetype" ] ;
fhir:use [ fhir:v "in" ] ;
fhir:min [ fhir:v "0"^^xsd:integer ] ;
fhir:max [ fhir:v "1" ] ;
fhir:type [ fhir:v "Coding" ]
] [
fhir:name [ fhir:v "return" ] ;
fhir:use [ fhir:v "out" ] ;
fhir:min [ fhir:v "0"^^xsd:integer ] ;
fhir:max [ fhir:v "1" ] ;
fhir:type [ fhir:v "Binary" ]
] ) . #
IG © 2021+ Den telemedicinske infrastruktur (eHealth Infrastructure). Package dk.ehealth.sundhed.fhir.ig.core#3.3.0 based on FHIR 4.0.1. Generated 2024-11-05