This page is part of the FUT Infrastructure (v3.3.0: Release) based on FHIR (HL7® FHIR® Standard) R4. This is the current published version in its permanent home (it will always be available at this URL). For a full list of available versions, see the Directory of published versions
Active as of 2019-02-08 |
{
"resourceType" : "ValueSet",
"id" : "ehealth-clinicalimpression-finding-codes",
"text" : {
"status" : "extensions",
"div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p class=\"res-header-id\"><b>Generated Narrative: ValueSet ehealth-clinicalimpression-finding-codes</b></p><a name=\"ehealth-clinicalimpression-finding-codes\"> </a><a name=\"hcehealth-clinicalimpression-finding-codes\"> </a><a name=\"ehealth-clinicalimpression-finding-codes-da-DK\"> </a><p>This value set includes codes based on the following rules:</p><ul><li>Include all codes defined in <a href=\"CodeSystem-ehealth-clinicalimpression-finding-codes.html\"><code>http://ehealth.sundhed.dk/cs/clinicalimpression-finding-codes</code></a></li><li>Import all the codes that are contained in <a href=\"ValueSet-ehealth-observation-codes.html\">Observation Codes</a></li><li>Include these codes as defined in <a href=\"http://www.snomed.org/\"><code>http://snomed.info/sct</code></a><table class=\"none\"><tr><td style=\"white-space:nowrap\"><b>Code</b></td><td><b>Display</b></td><td><b>English (United States) (English (United States), en)</b></td><td><b>Dansk (Danish, da)</b></td></tr><tr><td><a href=\"http://snomed.info/id/281300000\">281300000</a></td><td>Below reference range</td><td>Below reference range</td><td></td></tr><tr><td><a href=\"http://snomed.info/id/281302008\">281302008</a></td><td>Above reference range</td><td>Above reference range</td><td></td></tr><tr><td><a href=\"http://snomed.info/id/281301001\">281301001</a></td><td>Within reference range</td><td>Within reference range</td><td></td></tr><tr><td><a href=\"http://snomed.info/id/394844007\">394844007</a></td><td>Outside reference range</td><td>Outside reference range</td><td></td></tr><tr><td><a href=\"http://snomed.info/id/442686002\">442686002</a></td><td>Measurement finding below reference range</td><td>Measurement finding below reference range</td><td></td></tr><tr><td><a href=\"http://snomed.info/id/442756004\">442756004</a></td><td>Measurement finding above reference range</td><td>Measurement finding above reference range</td><td></td></tr><tr><td><a href=\"http://snomed.info/id/442082004\">442082004</a></td><td>Measurement finding within reference range</td><td>Measurement finding within reference range</td><td></td></tr><tr><td><a href=\"http://snomed.info/id/442096005\">442096005</a></td><td>Measurement finding outside reference range</td><td>Measurement finding outside reference range</td><td></td></tr><tr><td><a href=\"http://snomed.info/id/449171008\">449171008</a></td><td>Oxygen saturation below reference range</td><td>Oxygen saturation below reference range</td><td></td></tr><tr><td><a href=\"http://snomed.info/id/448225001\">448225001</a></td><td>Oxygen saturation within reference range</td><td>Oxygen saturation within reference range</td><td></td></tr></table></li><li>Include these codes as defined in <a href=\"CodeSystem-urn-oid-1.2.208.184.100.1.html\"><code>urn:oid:1.2.208.184.100.1</code></a><table class=\"none\"><tr><td style=\"white-space:nowrap\"><b>Code</b></td><td><b>Display</b></td><td><b>Definition</b></td><td><b>English (United States) (English (United States), en)</b></td><td><b>Dansk (Danish, da)</b></td></tr><tr><td><a href=\"CodeSystem-urn-oid-1.2.208.184.100.1.html#urn-oid-1.2.208.184.100.1-RAL\">RAL</a></td><td>Terapeutiske grænseværdier for RØD alarm</td><td>Terapeutiske grænseværdier for RØD alarm</td><td></td><td>Terapeutiske grænseværdier for RØD alarm</td></tr><tr><td><a href=\"CodeSystem-urn-oid-1.2.208.184.100.1.html#urn-oid-1.2.208.184.100.1-GAL\">GAL</a></td><td>Terapeutiske grænseværdier for GUL alarm</td><td>Terapeutiske grænseværdier for GUL alarm</td><td></td><td>Terapeutiske grænseværdier for GUL alarm</td></tr></table></li><li>Include these codes as defined in <a href=\"CodeSystem-ehealth-reference-range-type.html\"><code>http://ehealth.sundhed.dk/cs/reference-range-type</code></a><table class=\"none\"><tr><td style=\"white-space:nowrap\"><b>Code</b></td><td><b>Display</b></td><td><b>Definition</b></td><td><b>English (United States) (English (United States), en)</b></td><td><b>Dansk (Danish, da)</b></td></tr><tr><td><a href=\"CodeSystem-ehealth-reference-range-type.html#ehealth-reference-range-type-RELRAL\">RELRAL</a></td><td>Terapeutic relative reference range for RED alarm</td><td>Terapeutic relative reference range for RED alarm</td><td></td><td>Terapeutiske relative grænseværdier for RØD alarm</td></tr><tr><td><a href=\"CodeSystem-ehealth-reference-range-type.html#ehealth-reference-range-type-RELGAL\">RELGAL</a></td><td>Terapeutic relative reference range for YELLOW alarm</td><td>Terapeutic relative reference range for YELLOW alarm</td><td></td><td>Terapeutiske relative grænseværdier for GUL alarm</td></tr></table></li></ul></div>"
},
"url" : "http://ehealth.sundhed.dk/vs/clinicalimpression-finding-codes",
"version" : "3.3.0",
"name" : "ClinicalImpressionFindingCodes",
"title" : "ClinicalImpression Finding Codes",
"status" : "active",
"experimental" : true,
"date" : "2019-02-08T00:00:00+00:00",
"publisher" : "Den telemedicinske infrastruktur (eHealth Infrastructure)",
"contact" : [
{
"name" : "Den telemedicinske infrastruktur (eHealth Infrastructure)",
"telecom" : [
{
"system" : "url",
"value" : "http://ehealth.sundhed.dk"
}
]
}
],
"description" : "Value set of clinical impression finding codes.",
"jurisdiction" : [
{
"coding" : [
{
"system" : "urn:iso:std:iso:3166",
"code" : "DK",
"display" : "Denmark"
}
]
}
],
"compose" : {
"include" : [
{
"system" : "http://ehealth.sundhed.dk/cs/clinicalimpression-finding-codes"
},
{
"valueSet" : [
🔗 "http://ehealth.sundhed.dk/vs/observation-codes"
]
},
{
"system" : "http://snomed.info/sct",
"concept" : [
{
"code" : "281300000",
"display" : "Below reference range",
"designation" : [
{
"language" : "en-US",
"value" : "Below reference range"
}
]
},
{
"code" : "281302008",
"display" : "Above reference range",
"designation" : [
{
"language" : "en-US",
"value" : "Above reference range"
}
]
},
{
"code" : "281301001",
"display" : "Within reference range",
"designation" : [
{
"language" : "en-US",
"value" : "Within reference range"
}
]
},
{
"code" : "394844007",
"display" : "Outside reference range",
"designation" : [
{
"language" : "en-US",
"value" : "Outside reference range"
}
]
},
{
"code" : "442686002",
"display" : "Measurement finding below reference range",
"designation" : [
{
"language" : "en-US",
"value" : "Measurement finding below reference range"
}
]
},
{
"code" : "442756004",
"display" : "Measurement finding above reference range",
"designation" : [
{
"language" : "en-US",
"value" : "Measurement finding above reference range"
}
]
},
{
"code" : "442082004",
"display" : "Measurement finding within reference range",
"designation" : [
{
"language" : "en-US",
"value" : "Measurement finding within reference range"
}
]
},
{
"code" : "442096005",
"display" : "Measurement finding outside reference range",
"designation" : [
{
"language" : "en-US",
"value" : "Measurement finding outside reference range"
}
]
},
{
"code" : "449171008",
"display" : "Oxygen saturation below reference range",
"designation" : [
{
"language" : "en-US",
"value" : "Oxygen saturation below reference range"
}
]
},
{
"code" : "448225001",
"display" : "Oxygen saturation within reference range",
"designation" : [
{
"language" : "en-US",
"value" : "Oxygen saturation within reference range"
}
]
}
]
},
{
"system" : "urn:oid:1.2.208.184.100.1",
"concept" : [
{
"code" : "RAL",
"display" : "Terapeutiske grænseværdier for RØD alarm",
"designation" : [
{
"language" : "da",
"value" : "Terapeutiske grænseværdier for RØD alarm"
}
]
},
{
"code" : "GAL",
"display" : "Terapeutiske grænseværdier for GUL alarm",
"designation" : [
{
"language" : "da",
"value" : "Terapeutiske grænseværdier for GUL alarm"
}
]
}
]
},
{
"system" : "http://ehealth.sundhed.dk/cs/reference-range-type",
"concept" : [
{
"code" : "RELRAL",
"display" : "Terapeutic relative reference range for RED alarm",
"designation" : [
{
"language" : "da",
"value" : "Terapeutiske relative grænseværdier for RØD alarm"
}
]
},
{
"code" : "RELGAL",
"display" : "Terapeutic relative reference range for YELLOW alarm",
"designation" : [
{
"language" : "da",
"value" : "Terapeutiske relative grænseværdier for GUL alarm"
}
]
}
]
}
]
}
}