eHealth Infrastructure
3.1.0 - release

This page is part of the FUT Infrastructure (v3.1.0: Release) based on FHIR (HL7® FHIR® Standard) R4. This is the current published version in its permanent home (it will always be available at this URL). For a full list of available versions, see the Directory of published versions

Systematic Error Messages

  • GENERAL_RESOURCE_NOT_FOUND: Resource %s with id %s is not found.

  • GENERAL_SUBJECT_AND_CONTEXT_NOT_PROVIDED: At least one of subject and context must be provided.

  • GENERAL_VALIDATION_ERROR: Validation error: %s

  • GENERAL_EXPORT_FAILED: Export resource has failed.

  • GENERAL_CANONICAL_TARGET_NOT_ALLOWED_ERROR: Unsupported target in canonical: %s

  • GENERAL_NAMING_SYSTEM_NOT_FOUND: NamingSystem with identifier %s is not found.

ehealth-actionguidanceview

  • ACTIONGUIDANCEVIEW_ILLEGAL_CONTENT_SIZE: Size of content is greater than the max allowed size. Content size: %s, max size: %s

  • ACTIONGUIDANCEVIEW_ILLEGAL_STATUS_CHANGE: Illegal status change for action_guidance or view from %s and to %s

  • ACTIONGUIDANCEVIEW_ILLEGAL_CHANGE_OF_ELEMENTS: Illegal element change in either EHealthActonGuidance or EhealthView. If status is equal to Active or Retired, only the following elements can be changed (Recommendation, IntendedAudience, useContext, modifierrole and status)

ehealth-activitydefinition

  • ACTIVITYDEFINITION_UPDATE_ALLOWED_FOR_STATUS: Update is only allowed for ActivityDefinition with status: %s or %s.

  • ACTIVITYDEFINITION_UPDATE_TO_NOT_ALLOWED_STATE: Update is not allowed for ActivityDefinition with %s status to different than %s status.

  • ACTIVITYDEFINITION_SHARINGAPPROVALPOLICY_NOT_ALLOWED: Resource %s does not allow SharingApprovalPolicy to be set with code: %s %s.
  • ACTIVITYDEFINITION_SHARINGAPPROVALPOLICY_NOT_SET: Resource %s with code: %s %s must have SharingApprovalPolicy set.

ehealth-appointment

  • APPOINTMENT_LISTENER_APPOINTMENT_MISSING_CAREPLAN: Appointment has no CarePlan

ehealth-assembler

  • ASSEMBLER_QRD_FOUND_NON_OR_SEVERAL_MATCHES_FOR_QFDD_DOCUMENT_REFERENCE: Found non or more than 1 match for QFDD DocumentReference. Identifier: system: %s, value: %s.

  • ASSEMBLER_QRD_NOT_ABLE_TO_DETERMINE_QFDD_REFERENCE: Not able to determine QFDD reference from questionnaire.identifier. Non or more than 1 identifier system starting with ‘urn:oid’. Questionnaire: %s.

  • ASSEMBLER_QRD_QR_SOURCE_IS_UNSUPPORTED: QuestionnaireResponse with id: ‘%s’ has source ‘%s’, which is not supported - Skipping publication

  • ASSEMBLER_APD_MISSING_SUPPORTING_INFORMATION: Appointment must have supportingInformation

  • ASSEMBLER_APD_MISSING_PATIENT_PARTICIPANT: Appointment must have at least one Patient participant

  • ASSEMBLER_APD_MISSING_RESPONSIBLE_ORGANIZATION: Appointment must have responsible-organization

  • ASSEMBLER_APD_MISSING_PERFORMER: Appointment must have performer

  • ASSEMBLER_APD_MISSING_RESPONSIBLE_PRACTITIONER: Appointment must have responsible Practitioner

  • ASSEMBLER_APD_MISSING_PATIENT_CPR: Patient has no CPR number

  • ASSEMBLER_PHMR_UNKNOWN_AUTHOR_TYPE: Unknown author type:

ehealth-careplan

  • CAREPLAN_APPLY_NO_PLANDEFINITION: There is no PlanDefinition with id %s

  • CAREPLAN_APPLY_NOT_ACTIVE_PLANDEFINITION: The apply operation can only be performed on Plandefinitions with status “active”

  • CAREPLAN_APPLY_EPISODE_OF_CARE_REFERENCE_NOT_SPECIFIED: EpisodeOfCare reference must be specified

  • CAREPLAN_APPLY_PLAN_DEFINITION_REFERENCE_NOT_SPECIFIED: PlanDefinition reference must be specified

  • CAREPLAN_APPLY_CAN_NOT_FIND_ACTIVITY_DEFINITION: Can not find activity definition with id :%s

  • CAREPLAN_NOT_FOUND: CarePlan is not found.

  • CAREPLAN_SEARCH_SUBJECT_CONTEXT_OR_RESPONSIBLE_ACTOR_IS_NOT_SPECIFIED: At least subject, context or responsible actor must be specified

ehealth-careteam

  • CARETEAM_GENERAL_EXTERNAL_SECURITY_TOKEN_CARETEAM_IDENTIFIER_SYSTEM_IS_MISSING: The CareTeam must contain an identifier using system “urn:ietf:rfc:3986”

ehealth-communicationrequest

  • COMMUNICATIONREQUEST_CONTEXT_NOT_MATCHING_SERVICEREQUEST: The context for the CommunicationRequest: %s does not match the context of the referenced ServiceRequest: %s

  • COMMUNICATIONREQUEST_SUBJECT_NOT_MATCHING_RECIPIENT: Patient recipient: %s does not match the subject: %s

  • COMMUNICATIONREQUEST_SUBJECT_NOT_MATCHING_SERVICEREQUEST: The subject for the CommunicationRequest: %s does not match the subject of the referenced ServiceRequest: %s

  • COMMUNICATIONREQUEST_EXCACTLY_ONE_RECIPIENT_SEARCHPRARAM: Excactly one recipient search parameter required

ehealth-context

  • CONTEXT_VALIDATION_EPISODEOFCARE_EXCEPTION: Episode of care does not match the security token context

ehealth-definition

  • DEFINITION_WITHOUT_SELF_TREATMENT_TOPIC: %s has to be with self-treatment topic

ehealth-device

  • DEVICE_WRITE_WRONG_PATIENT_CONTEXT: User with patient context can only read devices that has been issued to the patient

  • DEVICE_WRITE_WRONG_ORGANIZATION_CONTEXT: User must be logged into the organization that is the owner of the device

  • DEVICE_METRIC_WRITE_WRONG_ORGANIZATION_CONTEXT: User must be logged into the organization that is the owner of the device

  • DEVICE_USE_STATEMENT_WRITE_WRONG_ORGANIZATION_CONTEXT: User must be logged into the organization that is the owner of the device

  • DEVICE_WRONG_PATIENT_CONTEXT: User with patient context can only interact with devices that has been issued to the patient or not issued to anyone yet

  • DEVICE_WRITE_NON_PRIVATELY_OWNED: Patient user can only create/update privately owned devices

ehealth-document

  • DOCUMENT_NOT_OF_TYPE_QFDD: The document is expected to be of type QFDD

  • DOCUMENT_QUERY_SOR_ORGANIZATION_REQUIRED: Security token organization context must be a SOR organization for query

  • DOCUMENT_QUERY_XDS_ERROR: The following errors where received from Document Sharing

  • DOCUMENT_QUERY_DOCUMENT_URL_NOT_CORRECT_FORMAT: Url doesn’t have expected format: __

  • DOCUMENT_QUERY_DOCUMENT_NOT_VALID_TYPE: Requested document type is not valid. The requested type was %s, but the operation only supports %s

  • DOCUMENT_QUERY_DOCUMENT_NOT_VALID_XML: Retrieved document is not valid XML

  • DOCUMENT_QUERY_REASON_NOT_PRESENT_WHEN_CONSENT_OVERRIDDEN: Reason is mandatory when the consent is overridden

ehealth-documentreference

  • DOCUMENTREFERENCE_SUBJECT_REFER_TO_PATIENT: It is not possible to set a patient as a subject for a Document reference

ehealth-episodeofcare

  • EPISODEOFCARE_CREATE_WRONG_EOC_COUNT: Bundle has to contain only one Episode of Care

  • EPISODEOFCARE_CREATE_UNSUPPORTED_RESOURCE_TYPE: Bundle contains unsupported resource type

  • EPISODEOFCARE_CREATE_INCORRECT_PROVENANCE_TARGET: Provenance has incorrect target

  • EPISODEOFCARE_CREATE_NO_REQUIRED_PROVENANCE_POLICIES: No provenance with required policies

  • EPISODEOFCARE_CREATE_INCORRECT_CONDITION_SUBJECT: EpisodeOfCare and Condition doesn’t point to the same Patient

  • EPISODEOFCARE_PATCH_NO_CONSENT: No valid Episode Of Care related consent

  • EPISODEOFCARE_CREATE_PATIENT_MUST_BE_ACTIVE_AND_NOT_DECEASED: Patient.active must be true and Patient.deceased must be false to create episode of care

  • EPISODEOFCARE_CREATE_STATUS_HISTORY_NOT_EMPTY: It is not allowed to fill status history manually

  • EPISODEOFCARE_CREATE_EPISODE_OF_CARE_IN_NON_PLANNED_STATUS: It is only possible to create an episode of care in status ‘Planned’

  • EPISODEOFCARE_CREATE_TEAM_HISTORY_NOT_EMPTY: It is not allowed to fill team history manually

  • EPISODEOFCARE_CREATE_PATIENT_DOESNT_MATCH_CONTEXT: Episode of care patient doesn’t match to the context

  • EPISODEOFCARE_IS_CONTEXT_ALLOWED_MATCH_NOT_FOUND: It is not possible to set the Episode Of Care as a context

ehealth-library

  • LIBRARY_EVALUATE_NO_INPUT_PARAMETER: An input parameter of type Parameters should be provided.

  • LIBRARY_EVALUATE_INCORRECT_INPUT_PARAMETER: Input parameter ‘parameters’ should contain exactly one resource of type QuestionnaireResponse, Observation or Media.

  • LIBRARY_EVALUATE_NO_RULE_DEFINED: Library with id %s do not contain a rule to use for evaluation.

  • LIBRARY_EVALUATE_NO_CAREPLAN_REFERENCING_PROVIDED_PROCEDUREQUEST: CarePlan with reference to ServiceRequest with id %s is not found.

  • LIBRARY_EVALUATE_RULE_SYNTAX_ERRORS: Syntax for rule is invalid. %s

  • LIBRARY_EVALUATE_OUTPUT_PARAMETER_NOT_SUPPORTED: Output parameter of type %s is not supported.

  • LIBRARY_EVALUATE_INPUT_PARAMETER_NOT_SUPPORTED: Input parameter of type %s is not supported.

  • LIBRARY_EVALUATE_UNEXPECTED_LIBRARY: Evaluate is invoked on Library with id %s. This Library is not the expected Library referenced by the ActivityDefinition.

  • LIBRARY_EVALUATE_UNABLE_TO_RESOLVE_RESOURCE: Not able to resolve %s when input is of type %s.

  • LIBRARY_EVALUATE_DURATION_UNIT_CODE_UNKNOWN: Unsupported code %s for Duration.code. Duration.code should be a valid UCUM code. Supported codes are (‘s’, ‘min’, ‘h’, ‘d’, ‘wk’, ‘mo’, ‘a’).

  • LIBRARY_EVALUATE_LOGIC_RULE_INVALID_INPUT: Error evaluating logic rule. Category: %s, Focus: %s, RuleDescription: %s

  • LIBRARY_IDENTIFIER_UPDATE_RESTRICTED: Validation error: attempt to update Library Identifiers list.

  • LIBRARY_UNKNOWN_IDENTIFIER: Unable to find unique Library with identifier: %s. Number of search results: %s

  • LIBRARY_MISSING_IDENTIFIER: Library %s does not have identifier of type: %s

ehealth-measurement

  • MEASUREMENT_SEARCHMEASUREMENT_PERIOD_NOT_SPECIFIED: Period must be specified

  • MEASUREMENT_SEARCHMEASUREMENT_PATIENT_AND_EPISODE_NOT_SPECIFIED: At least patient or episodeOfCare must be specified

  • MEASUREMENT_SEARCHMEASUREMENT_UNSUPPORTED_PATIENT_REFERENCE: Unsupported patient reference

  • MEASUREMENT_SEARCHMEASUREMENT_UNSUPPORTED_EPISODEOFCARE_REFERENCE: Unsupported episodeOfCare reference

  • MEASUREMENT_SEARCHMEASUREMENT_UNSUPPORTED_DEVICE_REFERENCE: Unsupported device reference

  • MEASUREMENT_SEARCHMEASUREMENT_UNSUPPORTED_BASEDON_REFERENCE: Unsupported based-on reference: %s

  • MEASUREMENT_SEARCHMEASUREMENT_REFERENCED_RESOURCE_NOT_FOUND: Referenced resource not found: %s

  • MEASUREMENT_SUBMITMEASUREMENT_INVALID_OBSERVATION_CODE: Observation.code does not match the code of the referenced ServiceRequest with id %s.

  • MEASUREMENT_SUBMITMEASUREMENT_INVALID_QUESTIONNAIRE_REFERENCE: Questionnaire reference with id %s is unexpected. Expected questionnaire reference to match questionnaire reference of related ActivityDefinition with id %s.

  • MEASUREMENT_SUBMITMEASUREMENT_INPUT_SHOULD_REFERENCE_PATIENT: Input resources of type EHealthObservation, EHealthMedia and EHealthQuestionnaireResponse should reference a patient.

  • MEASUREMENT_SUBMITMEASUREMENT_INPUT_SHOULD_REFERENCE_EPISODEOFCARE: Input resources of type EHealthObservation, EHealthMedia and EHealthQuestionnaireResponse should reference an episode of care.

  • MEASUREMENT_SUBMITMEASUREMENT_EMPTY_INPUT_BUNDLE: The input bundle does not contain any resources.

  • MEASUREMENT_SUBMITMEASUREMENT_INPUT_BUNDLE_CONTAINS_NONE_OF_EXPECTED_RESOURCES: The input bundle does not contain any resources of type EHealthObservation, EHealthMedia, EHealthQuestionnaireResponse.

  • MEASUREMENT_SUBMITMEASUREMENT_INPUT_BUNDLE_CONTAINS_INVALID_RESOURCES: The input bundle contains resources which are not of type EHealthObservation, EHealthMedia, EHealthQuestionnaireResponse or EHealthProvenance.

  • MEASUREMENT_SUBMITMEASUREMENT_INPUT_PROVENANCE_INVALID_POLICY: Submitted provenances should use the policy ‘Reuse of measurement chosen by citizen’

  • MEASUREMENT_SUBMITMEASUREMENT_INPUT_PROVENANCE_REFERENCE_MISSING: EHealthProvenance resource is referencing %s but it is not provided as part of the input.

  • MEASUREMENT_SUBMITMEASUREMENT_INPUT_PROVENANCE_NOT_SINGLE_TARGET: Provenance.target should have exactly one reference.

  • MEASUREMENT_SUBMITMEASUREMENT_INPUT_PROVENANCE_TARGET_AND_ENTITY_SHOULD_BE_SAME_TYPE: Provenance.target and Provenance.entity should be of same type.

  • MEASUREMENT_SUBMITMEASUREMENT_INPUT_PROVENANCE_TARGET_AND_ENTITY_SHOULD_REFERENCE_SAME_PATIENT: Provenance.target and Provenance.entity should reference the same patient

  • MEASUREMENT_SUBMITMEASUREMENT_INPUT_PROVENANCE_TARGET_AND_ENTITY_SHOULD_USE_SAME_DATE: Provenance.target and Provenance.entity should use the same date.

  • MEASUREMENT_SUBMITMEASUREMENT_INPUT_PROVENANCE_ENTITY_IS_REUSING: Provenance.entity is reusing another measurement and thus can not be used for reuse.

  • MEASUREMENT_SUBMITMEASUREMENT_INPUT_PROVENANCE_INVALID: %s is invalid.

  • MEASUREMENT_SUBMITMEASUREMENT_INPUT_PROVENANCE_NOT_SINGLE_ENTITY: Provenance.entity should have exactly one reference.

  • MEASUREMENT_SUBMITMEASUREMENT_INPUT_FOR_DIFFERENT_PATIENTS: The resources provided are for different patients.

  • MEASUREMENT_SUBMITMEASUREMENT_INPUT_NOT_PART_OF_SAME_EPISODEOFCARE: The resources provided are not all part of the same episode of care.

  • MEASUREMENT_SUBMITMEASUREMENT_PROCEDURE_REQUEST_IS_NOT_ACTIVE: Procedure request with id:[%s] is not active.

  • MEASUREMENT_SUBMITMEASUREMENT_ACTIVITYDEFINITION_MISSING_QUESTIONNAIRE_REFERENCE: ActivityDefinition with id %s does not contain a relatedArtifact with a Questionnaire reference

  • MEASUREMENT_SUBMITMEASUREMENT_DIFFERENT_PATIENT_REFERENCE: The patient referenced by the EpisodeOfCare is different than the patient referenced by the provided resources

  • MEASUREMENT_SUBMITMEASUREMENT_REUSE_NOT_ALLOWED: Reuse of resource with id %s is not allowed.

  • MEASUREMENT_SUBMITMEASUREMENT_ASSOCIATED_QUALITY_NOT_PRESENT: Associated quality %s is not present on submitted resource. Reuse of resource is not allowed.

  • MEASUREMENT_SUBMITMEASUREMENT_QUALITY_IS_NOT_SUBSUMED: Quality %s does not subsume %s. Reuse of resource is not allowed.

  • MEASUREMENT_SUBMITMEASUREMENT_RESOURCE_TO_OLD_TO_BE_USED_FOR_REUSE: Reuse of resource is not allowed due to the resource being too old.

  • MEASUREMENT_SUBMITMEASUREMENT_DURATION_UNIT_CODE_UNKNOWN: Unsupported code %s for Duration.code. Duration.code should be a valid UCUM code. Supported codes are (‘s’, ‘min’, ‘h’, ‘d’, ‘wk’, ‘mo’, ‘a’).

  • MEASUREMENT_SUBMITMEASUREMENT_MORE_THAN_ONE_DEVICE_QUALITY: Only one device quality allowed for each observation/media

  • MEASUREMENT_SUBMITMEASUREMENT_INVALID_RESOLVED_TIMING: ResolvedTiming must have either type=Resolved and start/end or type=Unresolved/Adhoc/Extra and no start/end

  • MEASUREMENT_GET_DATA_NO_DATA_FOUND: Encrypted media data with id %s was not found

ehealth-organization

  • ORGANIZATION_SOURCE_MUST_BE_MANUAL: The operation can only be performed for Organization with source “manual”

  • ORGANIZATION_IDENTIFIER_MUST_BE_SSL_WHEN_SOURCE_MANUAL: The operation can only be performed for SSL Organizations when the source is “manual”

  • ORGANIZATION_IDENTIFIER_NOT_UNIQUE: Organization Identifier not unique: %s

  • ORGANIZATION_IDENTIFIER_SYSTEM_NOT_ALLOWED_FOR_SOURCE_MANUAL: Identifier system is not allowed for Organization with source “manual”

  • ORGANIZATION_TRAVERSE_TO_SOR_NOT_POSSIBLE: No related SOR organization could be found for: %s

  • ORGANIZATION_IDENTIFIER_MUST_CONTAIN_AT_LEAST_CVR_FOR_SOURCE_MANUAL: Identifier system CVR required for Organization with source “manual”

  • ORGANIZATION_UNKNOWN_IDENTIFIER: Unable to find unique Organization with identifier: %s. Number of search results: %s

  • ORGANIZATION_MISSING_IDENTIFIER: Organization %s does not have identifier of type: %s

ehealth-plandefinition

  • PLANDEFINITION_UPDATE_ALLOWED_FOR_STATUS: Update is only allowed for PlanDefinition with status: %s or %s.

  • PLANDEFINITION_UPDATE_TO_NOT_ALLOWED_STATE: Update is not allowed for PlanDefinition with %s status to different than %s status.

  • PLANDEFINITION_VALIDATE_MANDATORY_ACTIVITYDEFINITION_OR_SUBPLAN_REFERENCE: At least one activity definition or subplan should be referenced.

  • PLANDEFINITION_VALIDATE_ALL_REFERENCED_ACTIVITYDEFINITIONS_OR_SUBPLANS_SHOULD_BE_ACTIVE: All referenced activity definitions or subplans should be with state: “active”

  • PLANDEFINITION_MISSING_RELATED_ACTION: An action points to a non-existing related action

ehealth-provenance

  • PROVENANCE_NO_READ_PRIVILEGE: User must be logged in with the provenance read privilege

  • PROVENANCE_NO_SEARCH_PRIVILEGE: User must be logged in with the provenance search privilege

  • PROVENANCE_SEARCH_DATA_NOT_MATCH_CONTEXT: The target property should match to the episode of care in context

ehealth-questionnaire

  • QUESTIONNAIRE_NOT_ALLOWED_TO_UPDATE_IN_STATUS: Update is not allowed for questionnaires with statuses: %s, %s

  • QUESTIONNAIRE_NOT_ALLOWED_TO_UPDATE_STATUS: Update is not allowed for questionnaires with %s status to different than %s status

  • QUESTIONNAIRE_NOT_ALLOWED_TO_DELETE_WITH_STATUS: Delete only possible for questionnaires with status: %s

  • QUESTIONNAIRE_IMAGE_FORMAT_VALIDATION_MESSAGE: %s Image in questionnaire item with linkID %s and Binary contentType %s does not match any code in ValueSet: %s

  • QUESTIONNAIRE_IMAGE_SIZE_VALIDATION_MESSAGE: %s Image in questionnaire item with linkID %s exceeds the maximum size of %s kB

  • QUESTIONNAIRE_QFDD_DOES_NOT_EXIST_IN_DOCUMENT_TRANSFORMATION: The QFDD with the identifier %s does not exist in document transformation

  • QUESTIONNAIRE_TERMINOLOGY_HELPER_CODE_NOT_FOUND: Code %s for CodeSystem %s not found

  • QUESTIONNAIRE_TERMINOLOGY_HELPER_CODE_SYSTEM_NOT_FOUND: Code system not found for url: %s

  • QUESTIONNAIRE_TERMINOLOGY_HELPER_CODE_SYSTEM_FOUND_MORE_THAN_ONE: Found more than one code system for url: %s

ehealth-reporting

  • REPORTING_MISSING_INPUT_PARAMETER: Parameter “%s” is mandatory for report “%s”.

  • REPORTING_REPORT_GENERATION_FAILED: Report generation has failed

  • REPORTING_SYNCHRONOUS_GENERATION_NOT_ALLOWED: Synchronous generation of the report is not allowed

  • REPORTING_SCHEDULE_NOT_ALLOWED: Scheduled generation of the report is not allowed

  • REPORTING_EXECUTE_NOT_ALLOWED: Asynchronous generation of the report is not allowed

  • REPORTING_MUTUALLY_EXCLUSIVE_INPUT_PARAMETER: Parameters “%s” and “%s” are mutually exclusive for report “%s”.

ehealth-security

  • SECURITY_TOKEN_CONTEXT_NOT_ALLOWED: Security token context not allowed: %s

  • SECURITY_TOKEN_INSUFFICIENT_PERMISSION: Insufficient permission for %s for %s

  • SECURITY_USER_NOT_ALLOWED: Resource not allowed for user: %s

  • SECURITY_TOKEN_CONTEXT_MISSING: Security token context missing for user type: %s

  • SECURITY_TOKEN_CONTEXT_MISSING_CONTEXT: Security token context missing for context type: %s

  • SECURITY_RESOURCE_NOT_MATCHING_TOKEN_CONTEXT: Resource not matching security token context: %s

  • SECURITY_OPERATION_NOT_ALLOWED_FOR_USER_TYPE: Operation not allowed for user type: %s

  • SECURITY_SEARCH_PARAM_NOT_MATCHING_TOKEN_CONTEXT: Search parameters not matching security token context: %s

  • SECURITY_SEARCH_PARAMS_MANDATORY: Search parameters mandatory with current user type and combination of search parameters: %s

  • SECURITY_SEARCH_OPERATION_POST_CONSTRAINT: Search on %s only supports POST style.

ehealth-status

  • STATUS_SCHEDULE_PAUSE_MAX_30_DAYS: A scheduled pause may not last more than 30 days

  • STATUS_SCHEDULE_IDENTICAL_TIME: Multiple status changes may not be scheduled to be activated simultaneously

ehealth-system

  • SYSTEM_TAG_UNEXPECTED_TAG: Resource contains system tag(s), which do not match related resource.

ehealth-task

  • TASK_INVESTIGATION_ITEM_REFERENCES_MUST_HAVE_VERSION_AND_VERSIONLESS: Investigation references must have an item with version and one versionless

  • TASK_RESTRICTION_CATEGORY_NONE_CANT_BE_COMBINED: Restriction category ‘None’ can’t be combined with others

  • TASK_RESTRICTION_CATEGORY_NOT_MATCHING_TOKEN_CONTEXT: Restriction category ‘%s’ does not match token context

  • TASK_MEASUREMENT_PROCESSING_FAILED: Measurement processing failed for Provenance %s

  • TASK_AUTOMATED_PROCESSING_RESOURCE_HANDLER_INVALID_JSON: Unable to parse json string: %s.

  • TASK_AUTOMATED_PROCESSING_INVALID_INPUT_RESOURCE: Resource of type %s is not a valid input resource.

  • TASK_AUTOMATED_PROCESSING_MISSING_MEASUREMENT_PROCEDURE_REQUEST: Could not determine if measurement is missing for procedure request: %s.

  • TASK_AUTOMATED_PROCESSING_FAILING_REQUESTS_JOB_TERMINATED: Limit of %s consecutive failing requests is reached. Scheduled audit job is terminated.

  • TASK_AUTOMATED_PROCESSING_CAREPLAN_NOT_FOUND: CarePlan is not found when searching by activity: %s.

  • TASK_AUTOMATED_PROCESSING_RULE_OUTPUT_NOT_FOUND: RuleOutput not found when searching through Task Automated Processing Resource

  • TASK_FOR_NOT_SET: When episode of care is set, the field ‘for’ must reference the corresponding patient

ehealth-transformation

  • TRANSFORMATION_DEPRECATE_DOCUMENT_CPR_DIDNT_MATCH: Found document didn’t match with CPR

  • TRANSFORMATION_DEPRECATE_DOCUMENT_MORE_THAN_ONE_FOUND: More than 1 DocumentReference with same master identifier found. The master identifier should be unique.

  • TRANSFORMATION_DEPRECATE_DOCUMENT_NO_DOCUMENT_FOUND: No matching document found

  • TRANSFORMATION_QFDD_XML_MISSING: Invalid input document reference, it must contain content with data of QFDD xml

  • TRANSFORMATION_QFDD_ITEM_WITH_SLIDER_MISSING_STEPVALUE: Questionnaire item with linkId ‘%s’ has itemControl: ‘slider’ but has no step value extension.

  • TRANSFORMATION_QFDD_ITEM_WITH_SLIDER_NOT_MATCHING_DISCRETE_SLIDER: Questionnaire item with linkId ‘%s’ has itemControl: ‘slider’ but maxOccursValue is not 1. Was: %s.

  • TRANSFORMATION_QRD_INVALID_INPUT_PARAMETERS: Input bundle should contain just one EHealthComposition, EHealthQuestionnaireResponse, EHealthQuestionnaire and DocumentReference(QFDD).

  • TRANSFORMATION_FROM_QRD_INVALID_INPUT_PARAMETERS: Input bundle should contain just one EHealthQuestionnaire and DocumentReference(QRD).

  • TRANSFORMATION_FROM_QRD_DUPLICATED_EXTERNAL_IDENTIFIER: Cannot transform from QRD to QuestionnaireResponse. Duplicated external identifiers: %s.

  • TRANSFORMATION_FROM_QRD_EXTERNAL_DOCUMENT_NOT_MATCHING_QFDD_IDENTIFIER_ON_QUESTIONNAIRE: External Document reference in QRD does not match QFDD identifier on Questionnaire. External Document reference: ‘%s’. QFDD identifier on Questionnaire: ‘%s’.

  • TRANSFORMATION_FROM_QRD_NO_EXTERNAL_DOCUMENT_FOUND_IN_QRD: No External Document reference found in QRD.

  • TRANSFORMATION_FROM_QRD_NO_QFDD_IDENTIFIER_ON_QUESTIONNAIRE: Questionnaire does not have a QFDD identifier. No identifier with system starting with ‘urn:oid’.

  • TRANSFORMATION_FROM_QRD_COULD_NOT_FIND_PARENT_FOR_LINK_ID: Could not find parent for item with linkId: %s.

  • TRANSFORMATION_FROM_QRD_QRD_HAS_NO_SECTIONS: QRD has no sections with questions.

  • TRANSFORMATION_FROM_QRD_QRD_QUESTION_TYPE_DOES_NOT_MATCH_QUESTIONNAIRE_ITEM_TYPE: QRD Question type ‘%s’ does not match questionnaire item type ‘%s’. LinkId: %s.

  • TRANSFORMATION_QRD_UNSUPPORTED_QUESTION_TYPE: Unsupported Questionnaire type: %s.

  • TRANSFORMATION_QRD_INVALID_NUMBER_OF_ANSWERS: QuestionnaireResponse item should contain from %s to %s answers.

  • TRANSFORMATION_QRD_SLIDER_MISMATCH_BETWEEN_TYPE_AND_SLIDER_STEP: Questionnaire item with linkId ‘%s’ has itemControl: ‘slider’ and item.type: ‘Integer’ but has decimal step value: %s.

  • TRANSFORMATION_QRD_INVALID_SLIDER_EXTENSIONS: Questionnaire item with linkId ‘%s’ has itemControl: ‘slider’, therefore it must contain at least the following extensions: %s.

  • TRANSFORMATION_QRD_NO_SLIDER_STEP_EXTENSION: Questionnaire item with linkId ‘%s’ has itemControl: ‘slider’, therefore it must contain one of the following extensions: %s.

  • TRANSFORMATION_QRD_NO_SLIDER_ITEM_CONTROL_EXTENSION: Questionnaire item with linkId ‘%s’ has no itemControl extension with code: ‘slider’.

  • TRANSFORMATION_QRD_MISSING_IDENTIFIER: Identifier on composition is mandatory

  • TRANSFORMATION_QRD_XML_MISSING: Invalid input document reference, it must contain content with data of QRD xml

  • TRANSFORMATION_QRD_EXPECTING_DISPLAY_ITEM_FOR_INFO_SECTION: QFDD section with title ‘%s’ has no organizers(Information Only Section). Expecting FHIR Questionnaire root group to have exactly one item of display. Found %s items.

  • TRANSFORMATION_QRD_EXPECTING_DISPLAY_ITEM_FOR_INFO_SECTION_FOUND_OTHER_TYPE: QFDD section with title ‘%s’ has no organizers(Information Only Section). Expecting FHIR Questionnaire root group to contain exactly one item of type ‘display’. Found item of type: ‘%s’.

  • TRANSFORMATION_QRD_NUMBER_OF_ITEMS_IN_ROOT_GROUP_DOES_NOT_MATCH_NUMBER_OF_ORGANIZERS: QFDD section with title ‘%s’ has %s organizers. Expect FHIR Questionnaire root group to contain the same number of items with type ‘group’. Found: %s.

  • TRANSFORMATION_QRD_EXPECTING_ONLY_SUB_GROUPS_IN_ROOT_GROUP: QFDD section with title ‘%s’ has %s organizers. Expect FHIR Questionnaire root group to contain only items of type: ‘group’.

  • TRANSFORMATION_QRD_EXPECTING_ROOT_ITEM_TO_BE_OF_TYPE_GROUP: Root item on questionnaire is not of type ‘group’. Type was: %s

  • TRANSFORMATION_QRD_EXPECTING_ITEM_TO_BE_OF_TYPE_GROUP: Item is not of type group. Type: %s

  • TRANSFORMATION_QRD_NUMBER_OF_ITEMS_ON_ROOT_LEVEL_DOES_NOT_MATCH_NUMBER_OF_SECTIONS: The number of root items on questionnaire does not match the number of QFDD sections. Questionnaire: %s.

  • TRANSFORMATION_QRD_FOUND_MORE_THAN_ONE_MATCH_FOR_LINKID_IN_QUESTIONNAIRE_RESPONSE: Found more than 1 match for LinkId in QuestionnaireResponse. LinkId: %s.

  • TRANSFORMATION_QRD_NO_MATCH_FOR_ASSOCIATED_TEXT_QUESTION_IN_QUESTIONNAIRE_RESPONSE: Found no match for associatedTextQuestion in QuestionnaireResponse. Found Questionnaire item with linkId: %s.

  • TRANSFORMATION_QRD_EXPECTING_QUESTIONNAIRE_TIEM_TO_HAVE_EXTERNAL_IDENTIFIER: Expected questionnaireItem to have externalIdentifier: %s. But was: %s

  • TRANSFORMATION_QRD_FOUND_NO_QUESTIONNAIRE_RESPONSE_FOR_ASSOCIATED_TEST_QUESTION: Found no QuestionnaireResponse for associatedTextQuestion. Found Questionnaire item with linkId: %s.

  • TRANSFORMATION_QRD_PRECONDITION_DO_NOT_MATCH_THE_QUESTION_FOR_ASSOCIATED_TEXT_QUESTION: The precondition criterion code does not match the expected question code. Expected: %s. But was: %s

  • TRANSFORMATION_QRD_MULTIPLE_CHOICE_ANSWER_EXPECTING_CODING_TYPE_FOR_VALUE: Expecting answer value to be of type Coding. QuestionResponseItem with linkId: %s.

  • TRANSFORMATION_QRD_PRECONDITION_GROUP_GROUP_TYPE_UNKNOWN: Unknown GroupType: %s

  • TRANSFORMATION_QRD_PRECONDITION_MORE_THAN_ONE: Transformation do not support more than one precondition for associatedTextQuestion. Found %s. AssociatedTextQuestion: %s

  • TRANSFORMATION_QRD_EXPECT_IMAGE_IN_QUESTIONNAIRE_ITEM: Expecting QuestionnaireItem to have an image as the corresponding QFDD question has an image. Question id: %s

  • TRANSFORMATION_QRD_NOT_EXPECTING_IMAGE_IN_QUESTIONNAIRE_ITEM: Not expecting QuestionnaireItem to have an image as the corresponding QFDD question do not have an image. Question id: %s

  • TRANSFORMATION_QRD_UNKNOWN_QRD_RESPONSE_TYPE: Unknown QRD response type. QRD Question id: %s

  • TRANSFORMATION_QRD_ASSOCIATED_TEXT_QUESTION_ITEM_NOT_OF_TYPE_TEXT: AssociatedTextQuestion item with id: ‘%s’ is not of type ‘text’. Type was: %s

  • TRANSFORMATION_QRD_QFDD_QUESTION_DOES_NOT_SUPPORT_ASSOCIATED_TEXT_QUESTION: QFDDQuestion with id: ‘%s’ does not support associatedText. Class was: %s

  • TRANSFORMATION_PHMR_MISSING_RESOURCE: Input bundle missing resource: %s

  • TRANSFORMATION_PHMR_NARRATIVE_ERROR: Can’t generate narrative for: %s

  • TRANSFORMATION_HEADER_MISSING_CPR: CPR is mandatory for patient but not present in fhir bundle

  • TRANSFORMATION_PHMR_INVALID_OBSERVATION_CODING: Observation coding system must be urn:oid:1.2.208.176.2.1

  • TRANSFORMATION_PHMR_INVALID_OBSERVATION_COMMENT_AUTHOR_REFERENCE: The author of a measurement comment is a reference not provided in the bundle.

  • TRANSFORMATION_PHMR_INVALID_OBSERVATION_RANGES_CODING: Observation.observationRanges[x].type.coding.system should be http://www.example.com/medcom/message-codes

  • TRANSFORMATION_PHMR_INVALID_OBSERVATION_RANGES: Observation ranges should not have both High and Low set when transforming to PHRM, but High is: %s, and Low is: %s

  • TRANSFORMATION_PHMR_INVALID_NUMBER_OF_DECIMALS: Value should have no more than 7 decimals, but is: %s

  • TRANSFORMATION_PHMR_OBSERVATION_QUANTITY_MISSING: Value should be Quantity type and not null

  • TRANSFORMATION_PHMR_XML_MISSING: Invalid input document reference, it must contain content with data of PHMR xml

  • TRANSFORMATION_PHMR_ID_OID_NOT_FOUND: NamingSystem or CodeSystem with url %s is not found.

  • TRANSFORMATION_PHMR_MISSING_MEASUREMENT_IDENTIFIER: No identifier found for measurement

  • TRANSFORMATION_PHMR_DOCUMENT_TIME_INTERVAL_MISSING: Document is missing serviceStartTime and serviceStopTime.

  • TRANSFORMATION_PHMR_DOCUMENT_INVALID_EFFECTIVE: Invalid Observation.effective, expecting DateTime, Period or Instant

  • TRANSFORMATION_PHMR_MEASUREMENT_INVALID_METHOD_CODES: Method codes for performerType and provisionMethod for observation with id ‘%s’ could not be established.

  • TRANSFORMATION_HEADER_MISSING_CONFIDENTIALITY_CODE: Composition.confidentiality is mandatory

  • TRANSFORMATION_HEADER_WRONG_TYPE_COMPOSITION_SUBJECT: Composition.subject should be a Patient

  • TRANSFORMATION_HEADER_MISSING_CUSTODIAN: Custodian is mandatory for transformation

  • TRANSFORMATION_HEADER_MISSING_COMPOSITION: Composition expected for transformation is not found

  • TRANSFORMATION_HEADER_MISSING_ATTESTER: Composition.attester.party is mandatory for transformation

  • TRANSFORMATION_HEADER_WRONG_TYPE_COMPOSITION_AUTHOR: Composition.author should either be a Patient or Practitioner

  • TRANSFORMATION_HEADER_MISSING_COMPOSITION_AUTHOR_ORGANIZATION: Composition.authorOrganization is mandatory for transformation

  • TRANSFORMATION_HEADER_AUTHOR_ORGANIZATION_MUST_CONTAIN_SOR_ID: Composition.authorOrganization must contain SOR identifier: %s

  • TRANSFORMATION_HEADER_ATTESTER_ORGANIZATION_MUST_CONTAIN_SOR_ID: Composition.attester.party must contain SOR identifier: %s

  • TRANSFORMATION_HEADER_CUSTODIAN_MUST_CONTAIN_SOR_ID: Custodian organization must contain SOR identifier: %s

  • TRANSFORMATION_HEADER_COMPOSITION_HAS_NO_TIMEZONE_OR_SECONDS: Composition has no timezone or seconds set: %s

  • TRANSFORMATION_XDS_PROPERTY_MISSING_EXCEPTION: ‘%s’ is missing which is required for document sharing. DocumentReference id: ‘%s’.

  • TRANSFORMATION_XDS_PROPERTY_CODE_INVALID_EXCEPTION: ‘%s’ is required for document sharing but the specified coding is not valid for the valueSet ‘%s’: system=%s, code=%s, display=%s. DocumentReference id: ‘%s’

  • TRANSFORMATION_APD_XML_MISSING: Invalid input document reference, it must contain content with data of APD xml

ehealth-upload

  • UPLOAD_QFDD_MASTERIDENTIFIER_IS_ALREADY_IN_USE: The masterIdentifier on the DocumentReference is not unique

  • UPLOAD_QFDD_THE_ID_OF_THE_DOCUMENT_IS_NULL: Missing Id in the QFDD.

ehealth-versioning

  • VERSIONING_RESOURCE_MUST_BE_FROM_CURRENT_ENVIRONMENT: Versioning validation error: Resource must be from current environment: %s.

  • VERSIONING_MULTIPLE_DRAFTS_IN_BASE_NOT_ALLOWED: Versioning validation error: Only one draft resource at a time is allowed per base.

  • VERSIONING_RESOURCE_NOT_ELIGIBLE_FOR_CLONE: Versioning validation error: A resource must have base-identifier, environment-identifier, versioning-identifier and version to be cloned.

  • VERSIONING_REFERENCE_NOT_RELEVANT_FOR_RESOURCE: Versioning validation error: References included in deep_clone_references must be present in resource to clone, %s: %s.

  • VERSIONING_REFERENCE_MISSING_IN_TREE_PATH: Versioning validation error: The following resources could not be cloned since their parent resource, %s, is not present in deep_clone_refernces: %s.