eHealth Infrastructure
3.3.0 - release Denmark flag

This page is part of the FUT Infrastructure (v3.3.0: Release) based on FHIR (HL7® FHIR® Standard) R4. This is the current published version. For a full list of available versions, see the Directory of published versions

: patientCPRIdentifierUnique - JSON Representation

Active as of 2022-11-15

Raw json | Download

{
  "resourceType" : "SearchParameter",
  "id" : "ehealth-patient-search-cpridentifier-unique",
  "text" : {
    "status" : "generated",
    "div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p class=\"res-header-id\"><b>Generated Narrative: SearchParameter ehealth-patient-search-cpridentifier-unique</b></p><a name=\"ehealth-patient-search-cpridentifier-unique\"> </a><a name=\"hcehealth-patient-search-cpridentifier-unique\"> </a><a name=\"ehealth-patient-search-cpridentifier-unique-da-DK\"> </a><h2>patientCPRIdentifierUnique</h2><p>Parameter <code>patientCPRIdentifierUnique</code>:<code>token</code></p><div><p>Uniqueness constraint on search parameter patientCPRIdentifier</p>\n</div><table class=\"grid\"><tr><td>Resource</td><td><a href=\"http://hl7.org/fhir/R4/patient.html\">Patient</a></td></tr><tr><td>Expression</td><td><code>Patient.identifier.where(system = 'urn:oid:1.2.208.176.1.2').value</code></td></tr><tr><td>Processing Mode</td><td>Normal</td></tr><tr><td>Multiples</td><td><ul><li>multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true</li><li>multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true</li></ul></td></tr></table><p><b>Comparators</b></p><table class=\"grid\"><tr><td><a href=\"SearchParameter-ehealth-patient-search-cpridentifier.html\">patientCPRIdentifier</a></td><td><code>Patient</code></td></tr></table></div>"
  },
  "extension" : [
    {
      "url" : "http://hapifhir.io/fhir/StructureDefinition/sp-unique",
      "valueBoolean" : true
    }
  ],
  "url" : "http://ehealth.sundhed.dk/fhir/SearchParameter/Patient/cprIdentifierUnique",
  "version" : "3.3.0",
  "name" : "patientCPRIdentifierUnique",
  "status" : "active",
  "date" : "2022-11-15T08:31:20+00:00",
  "publisher" : "Den telemedicinske infrastruktur (eHealth Infrastructure)",
  "contact" : [
    {
      "name" : "Den telemedicinske infrastruktur (eHealth Infrastructure)",
      "telecom" : [
        {
          "system" : "url",
          "value" : "http://ehealth.sundhed.dk"
        }
      ]
    }
  ],
  "description" : "Uniqueness constraint on search parameter patientCPRIdentifier",
  "jurisdiction" : [
    {
      "coding" : [
        {
          "system" : "urn:iso:std:iso:3166",
          "code" : "DK",
          "display" : "Denmark"
        }
      ]
    }
  ],
  "code" : "patientCPRIdentifierUnique",
  "base" : [
    "Patient"
  ],
  "type" : "token",
  "expression" : "Patient.identifier.where(system = 'urn:oid:1.2.208.176.1.2').value",
  "xpathUsage" : "normal",
  "component" : [
    {
      "definition" : "http://ehealth.sundhed.dk/fhir/SearchParameter/Patient/cprIdentifier",
      "expression" : "Patient"
    }
  ]
}