eHealth Infrastructure
3.2.0 - release

This page is part of the FUT Infrastructure (v3.2.0: Release) based on FHIR (HL7® FHIR® Standard) R4. This is the current published version in its permanent home (it will always be available at this URL). For a full list of available versions, see the Directory of published versions

Error Messages

Error messages

The following list contains the error messages that are defined for the eHealth Infrastructure. The error messages are grouped by profile and follows the pattern <PROFILENAME>_<OPERATION>_<ERROR>. The pattern is used to determine which operation can result in the specific error. Note that general errors follows the pattern GENERAL_<ERROR>.

If a requests result in an error, the error message can be obtained from the diagnostics element for the specific entry in the returned issue list:

{
    "resourceType": "OperationOutcome",
    ...
    "issue": [
        {
            "severity": "error",
            "code": "processing",
            "diagnostics": "Update is only allowed for PlanDefinition with status: DRAFT or ACTIVE."
        }
    ]
}

General errors

  • GENERAL_EXTERNAL_RESOURCE_REFERENCE_NOT_FOUND: External resource reference not found: %s
  • GENERAL_JSON_PATCH_VALIDATION_FAILED: JSON patch validation failed: %s
  • GENERAL_FORBIDDEN_JSON_PATCH_PATH: Forbidden JSON PATCH path: %s
  • GENERAL_META_DELETE_PROFILE_FORBIDDEN: Profiles cannot be deleted. Attempted to delete profile: %s
  • GENERAL_INTERNAL_ERROR: Detailed error: %s
  • GENERAL_RESOURCE_NOT_FOUND: Resource %s with id %s is not found.

  • GENERAL_SUBJECT_AND_CONTEXT_NOT_PROVIDED: At least one of subject and context must be provided.

  • GENERAL_VALIDATION_ERROR: Validation error: %s

  • GENERAL_EXPORT_FAILED: Export resource has failed.

  • GENERAL_CANONICAL_TARGET_NOT_ALLOWED_ERROR: Unsupported target in canonical: %s

  • GENERAL_NAMING_SYSTEM_NOT_FOUND: NamingSystem with identifier %s is not found.

ehealth-actionguidanceview

  • ACTIONGUIDANCEVIEW_ILLEGAL_CONTENT_SIZE: Size of content is greater than the max allowed size. Content size: %s, max size: %s

  • ACTIONGUIDANCEVIEW_ILLEGAL_STATUS_CHANGE: Illegal status change for action_guidance or view from %s and to %s

  • ACTIONGUIDANCEVIEW_ILLEGAL_CHANGE_OF_ELEMENTS: Illegal element change in either EHealthActonGuidance or EhealthView. If status is equal to Active or Retired, only the following elements can be changed (Recommendation, IntendedAudience, useContext, modifierrole and status)

ehealth-activitydefinition

  • ACTIVITYDEFINITION_UPDATE_ALLOWED_FOR_STATUS: Update is only allowed for ActivityDefinition with status: %s or %s.

  • ACTIVITYDEFINITION_UPDATE_TO_NOT_ALLOWED_STATE: Update is not allowed for ActivityDefinition with %s status to different than %s status.

  • ACTIVITYDEFINITION_SHARINGAPPROVALPOLICY_NOT_ALLOWED: Resource %s does not allow SharingApprovalPolicy to be set with code: %s %s.
  • ACTIVITYDEFINITION_SHARINGAPPROVALPOLICY_NOT_SET: Resource %s with code: %s %s must have SharingApprovalPolicy set.

ehealth-appointment

  • APPOINTMENT_LISTENER_APPOINTMENT_MISSING_CAREPLAN: Appointment has no CarePlan

ehealth-assembler

  • ASSEMBLER_QRD_FOUND_NON_OR_SEVERAL_MATCHES_FOR_QFDD_DOCUMENT_REFERENCE: Found non or more than 1 match for QFDD DocumentReference. Identifier: system: %s, value: %s.

  • ASSEMBLER_QRD_NOT_ABLE_TO_DETERMINE_QFDD_REFERENCE: Not able to determine QFDD reference from questionnaire.identifier. Non or more than 1 identifier system starting with 'urn:oid'. Questionnaire: %s.

  • ASSEMBLER_QRD_QR_SOURCE_IS_UNSUPPORTED: QuestionnaireResponse with id: '%s' has source '%s', which is not supported - Skipping publication

  • ASSEMBLER_APD_MISSING_SUPPORTING_INFORMATION: Appointment must have supportingInformation

  • ASSEMBLER_APD_MISSING_PATIENT_PARTICIPANT: Appointment must have at least one Patient participant

  • ASSEMBLER_APD_MISSING_RESPONSIBLE_ORGANIZATION: Appointment must have responsible-organization

  • ASSEMBLER_APD_MISSING_PERFORMER: Appointment must have performer

  • ASSEMBLER_APD_MISSING_RESPONSIBLE_PRACTITIONER: Appointment must have responsible Practitioner

  • ASSEMBLER_APD_MISSING_PATIENT_CPR: Patient has no CPR number

  • ASSEMBLER_PHMR_UNKNOWN_AUTHOR_TYPE: Unknown author type:

ehealth-careplan

  • CAREPLAN_APPLY_NO_PLANDEFINITION: There is no PlanDefinition with id %s

  • CAREPLAN_APPLY_NOT_ACTIVE_PLANDEFINITION: The apply operation can only be performed on Plandefinitions with status "active"

  • CAREPLAN_APPLY_EPISODE_OF_CARE_REFERENCE_NOT_SPECIFIED: EpisodeOfCare reference must be specified

  • CAREPLAN_APPLY_PLAN_DEFINITION_REFERENCE_NOT_SPECIFIED: PlanDefinition reference must be specified

  • CAREPLAN_APPLY_CAN_NOT_FIND_ACTIVITY_DEFINITION: Can not find activity definition with id :%s

  • CAREPLAN_NOT_FOUND: CarePlan is not found.

  • CAREPLAN_SEARCH_SUBJECT_CONTEXT_OR_RESPONSIBLE_ACTOR_IS_NOT_SPECIFIED: At least subject, context or responsible actor must be specified

ehealth-careteam

  • CARETEAM_GENERAL_EXTERNAL_SECURITY_TOKEN_CARETEAM_IDENTIFIER_SYSTEM_IS_MISSING: The CareTeam must contain an identifier using system "urn:ietf:rfc:3986"

ehealth-cda

  • CDA_XML_VALIDATION_FAILED: Validation of the CDA XML failed: %s

ehealth-communicationrequest

  • COMMUNICATIONREQUEST_CONTEXT_NOT_MATCHING_SERVICEREQUEST: The context for the CommunicationRequest: %s does not match the context of the referenced ServiceRequest: %s

  • COMMUNICATIONREQUEST_SUBJECT_NOT_MATCHING_RECIPIENT: Patient recipient: %s does not match the subject: %s

  • COMMUNICATIONREQUEST_SUBJECT_NOT_MATCHING_SERVICEREQUEST: The subject for the CommunicationRequest: %s does not match the subject of the referenced ServiceRequest: %s

  • COMMUNICATIONREQUEST_EXCACTLY_ONE_RECIPIENT_SEARCHPRARAM: Excactly one recipient search parameter required

ehealth-context

  • CONTEXT_VALIDATION_EPISODEOFCARE_EXCEPTION: Episode of care does not match the security token context

ehealth-definition

  • DEFINITION_WITHOUT_SELF_TREATMENT_TOPIC: %s has to be with self-treatment topic

ehealth-device

  • DEVICE_WRITE_WRONG_PATIENT_CONTEXT: User with patient context can only read devices that has been issued to the patient

  • DEVICE_WRITE_WRONG_ORGANIZATION_CONTEXT: User must be logged into the organization that is the owner of the device

  • DEVICE_METRIC_WRITE_WRONG_ORGANIZATION_CONTEXT: User must be logged into the organization that is the owner of the device

  • DEVICE_USE_STATEMENT_WRITE_WRONG_ORGANIZATION_CONTEXT: User must be logged into the organization that is the owner of the device

  • DEVICE_WRONG_PATIENT_CONTEXT: User with patient context can only interact with devices that has been issued to the patient or not issued to anyone yet

  • DEVICE_WRITE_NON_PRIVATELY_OWNED: Patient user can only create/update privately owned devices

ehealth-document

  • DOCUMENT_NOT_OF_TYPE_QFDD: The document is expected to be of type QFDD

  • DOCUMENT_QUERY_SOR_ORGANIZATION_REQUIRED: Security token organization context must be a SOR organization for query

  • DOCUMENT_QUERY_XDS_ERROR: The following errors where received from Document Sharing

  • DOCUMENT_QUERY_DOCUMENT_URL_NOT_CORRECT_FORMAT: Url doesn't have expected format: __

  • DOCUMENT_QUERY_DOCUMENT_NOT_VALID_TYPE: Requested document type is not valid. The requested type was %s, but the operation only supports %s

  • DOCUMENT_QUERY_DOCUMENT_NOT_VALID_XML: Retrieved document is not valid XML

  • DOCUMENT_QUERY_REASON_NOT_PRESENT_WHEN_CONSENT_OVERRIDDEN: Reason is mandatory when the consent is overridden

ehealth-documentreference

  • DOCUMENTREFERENCE_SUBJECT_REFER_TO_PATIENT: It is not possible to set a patient as a subject for a Document reference

ehealth-episodeofcare

  • EPISODEOFCARE_CREATE_WRONG_EOC_COUNT: Bundle has to contain only one Episode of Care

  • EPISODEOFCARE_CREATE_UNSUPPORTED_RESOURCE_TYPE: Bundle contains unsupported resource type

  • EPISODEOFCARE_CREATE_INCORRECT_PROVENANCE_TARGET: Provenance has incorrect target

  • EPISODEOFCARE_CREATE_NO_REQUIRED_PROVENANCE_POLICIES: No provenance with required policies

  • EPISODEOFCARE_CREATE_INCORRECT_CONDITION_SUBJECT: EpisodeOfCare and Condition doesn't point to the same Patient

  • EPISODEOFCARE_PATCH_NO_CONSENT: No valid Episode Of Care related consent

  • EPISODEOFCARE_CREATE_PATIENT_MUST_BE_ACTIVE_AND_NOT_DECEASED: Patient.active must be true and Patient.deceased must be false to create episode of care

  • EPISODEOFCARE_CREATE_STATUS_HISTORY_NOT_EMPTY: It is not allowed to fill status history manually

  • EPISODEOFCARE_CREATE_EPISODE_OF_CARE_IN_NON_PLANNED_STATUS: It is only possible to create an episode of care in status 'Planned'

  • EPISODEOFCARE_CREATE_TEAM_HISTORY_NOT_EMPTY: It is not allowed to fill team history manually

  • EPISODEOFCARE_CREATE_PATIENT_DOESNT_MATCH_CONTEXT: Episode of care patient doesn't match to the context

  • EPISODEOFCARE_IS_CONTEXT_ALLOWED_MATCH_NOT_FOUND: It is not possible to set the Episode Of Care as a context

ehealth-library

  • LIBRARY_EVALUATE_NO_INPUT_PARAMETER: An input parameter of type Parameters should be provided.

  • LIBRARY_EVALUATE_INCORRECT_INPUT_PARAMETER: Input parameter 'parameters' should contain exactly one resource of type QuestionnaireResponse, Observation or Media.

  • LIBRARY_EVALUATE_NO_RULE_DEFINED: Library with id %s do not contain a rule to use for evaluation.

  • LIBRARY_EVALUATE_NO_CAREPLAN_REFERENCING_PROVIDED_PROCEDUREQUEST: CarePlan with reference to ServiceRequest with id %s is not found.

  • LIBRARY_EVALUATE_RULE_SYNTAX_ERRORS: Syntax for rule is invalid. %s

  • LIBRARY_EVALUATE_OUTPUT_PARAMETER_NOT_SUPPORTED: Output parameter of type %s is not supported.

  • LIBRARY_EVALUATE_INPUT_PARAMETER_NOT_SUPPORTED: Input parameter of type %s is not supported.

  • LIBRARY_EVALUATE_UNEXPECTED_LIBRARY: Evaluate is invoked on Library with id %s. This Library is not the expected Library referenced by the ActivityDefinition.

  • LIBRARY_EVALUATE_UNABLE_TO_RESOLVE_RESOURCE: Not able to resolve %s when input is of type %s.

  • LIBRARY_EVALUATE_DURATION_UNIT_CODE_UNKNOWN: Unsupported code %s for Duration.code. Duration.code should be a valid UCUM code. Supported codes are ('s', 'min', 'h', 'd', 'wk', 'mo', 'a').

  • LIBRARY_EVALUATE_LOGIC_RULE_INVALID_INPUT: Error evaluating logic rule. Category: %s, Focus: %s, RuleDescription: %s

  • LIBRARY_IDENTIFIER_UPDATE_RESTRICTED: Validation error: attempt to update Library Identifiers list.

  • LIBRARY_UNKNOWN_IDENTIFIER: Unable to find unique Library with identifier: %s. Number of search results: %s

  • LIBRARY_MISSING_IDENTIFIER: Library %s does not have identifier of type: %s

ehealth-measurement

  • MEASUREMENT_SEARCHMEASUREMENT_PERIOD_NOT_SPECIFIED: Period must be specified

  • MEASUREMENT_SEARCHMEASUREMENT_PATIENT_AND_EPISODE_NOT_SPECIFIED: At least patient or episodeOfCare must be specified

  • MEASUREMENT_SEARCHMEASUREMENT_PATIENT_AND_EPISODE_AND_SERVICEREQUEST_NOT_SPECIFIED: At least one patient, episodeOfCare or serviceRequest must be specified

  • MEASUREMENT_SEARCHMEASUREMENT_COUNT_NOT_SPECIFIED: A positive number for Count must be specified

  • MEASUREMENT_SEARCHMEASUREMENT_COUNT_LIMIT_EXCEEDED: Count limit of 100 exceeded

  • MEASUREMENT_SEARCHMEASUREMENT_START_OR_END_NOT_SPECIFIED: Either start or end must be provided, but none was provided

  • MEASUREMENT_SEARCHMEASUREMENT_START_AND_END_BOTH_SPECIFIED: Both start and end cannot be specified

  • MEASUREMENT_SEARCHMEASUREMENT_UNSUPPORTED_REFERENCE: Unsupported resource reference, expected %s but was %s

  • MEASUREMENT_SEARCHMEASUREMENT_UNSUPPORTED_DEVICE_REFERENCE: Unsupported device reference

  • MEASUREMENT_SEARCHMEASUREMENT_UNSUPPORTED_BASEDON_REFERENCE: Unsupported based-on reference: %s

  • MEASUREMENT_SEARCHMEASUREMENT_REFERENCED_RESOURCE_NOT_FOUND: Referenced resource not found: %s

  • MEASUREMENT_SUBMITMEASUREMENT_INVALID_OBSERVATION_CODE: Observation.code does not match the code of the referenced ServiceRequest with id %s.

  • MEASUREMENT_SUBMITMEASUREMENT_INVALID_QUESTIONNAIRE_REFERENCE: Questionnaire reference with id %s is unexpected. Expected questionnaire reference to match questionnaire reference of related ActivityDefinition with id %s.

  • MEASUREMENT_SUBMITMEASUREMENT_INPUT_SHOULD_REFERENCE_PATIENT: Input resources of type EHealthObservation, EHealthMedia and EHealthQuestionnaireResponse should reference a patient.

  • MEASUREMENT_SUBMITMEASUREMENT_INPUT_SHOULD_REFERENCE_EPISODEOFCARE: Input resources of type EHealthObservation, EHealthMedia and EHealthQuestionnaireResponse should reference an episode of care.

  • MEASUREMENT_SUBMITMEASUREMENT_EMPTY_INPUT_BUNDLE: The input bundle does not contain any resources.

  • MEASUREMENT_SUBMITMEASUREMENT_INPUT_BUNDLE_CONTAINS_NONE_OF_EXPECTED_RESOURCES: The input bundle does not contain any resources of type EHealthObservation, EHealthMedia, EHealthQuestionnaireResponse.

  • MEASUREMENT_SUBMITMEASUREMENT_INPUT_BUNDLE_CONTAINS_INVALID_RESOURCES: The input bundle contains resources which are not of type EHealthObservation, EHealthMedia, EHealthQuestionnaireResponse or EHealthProvenance.

  • MEASUREMENT_SUBMITMEASUREMENT_INPUT_PROVENANCE_INVALID_POLICY: Submitted provenances should use the policy 'Reuse of measurement chosen by citizen'

  • MEASUREMENT_SUBMITMEASUREMENT_INPUT_PROVENANCE_REFERENCE_MISSING: EHealthProvenance resource is referencing %s but it is not provided as part of the input.

  • MEASUREMENT_SUBMITMEASUREMENT_INPUT_PROVENANCE_NOT_SINGLE_TARGET: Provenance.target should have exactly one reference.

  • MEASUREMENT_SUBMITMEASUREMENT_INPUT_PROVENANCE_TARGET_AND_ENTITY_SHOULD_BE_SAME_TYPE: Provenance.target and Provenance.entity should be of same type.

  • MEASUREMENT_SUBMITMEASUREMENT_INPUT_PROVENANCE_TARGET_AND_ENTITY_SHOULD_REFERENCE_SAME_PATIENT: Provenance.target and Provenance.entity should reference the same patient

  • MEASUREMENT_SUBMITMEASUREMENT_INPUT_PROVENANCE_TARGET_AND_ENTITY_SHOULD_USE_SAME_DATE: Provenance.target and Provenance.entity should use the same date.

  • MEASUREMENT_SUBMITMEASUREMENT_INPUT_PROVENANCE_ENTITY_IS_REUSING: Provenance.entity is reusing another measurement and thus can not be used for reuse.

  • MEASUREMENT_SUBMITMEASUREMENT_INPUT_PROVENANCE_INVALID: %s is invalid.

  • MEASUREMENT_SUBMITMEASUREMENT_INPUT_PROVENANCE_NOT_SINGLE_ENTITY: Provenance.entity should have exactly one reference.

  • MEASUREMENT_SUBMITMEASUREMENT_INPUT_FOR_DIFFERENT_PATIENTS: The resources provided are for different patients.

  • MEASUREMENT_SUBMITMEASUREMENT_INPUT_NOT_PART_OF_SAME_EPISODEOFCARE: The resources provided are not all part of the same episode of care.

  • MEASUREMENT_SUBMITMEASUREMENT_PROCEDURE_REQUEST_IS_NOT_ACTIVE: Procedure request with id:[%s] is not active.

  • MEASUREMENT_SUBMITMEASUREMENT_ACTIVITYDEFINITION_MISSING_QUESTIONNAIRE_REFERENCE: ActivityDefinition with id %s does not contain a relatedArtifact with a Questionnaire reference

  • MEASUREMENT_SUBMITMEASUREMENT_DIFFERENT_PATIENT_REFERENCE: The patient referenced by the EpisodeOfCare is different than the patient referenced by the provided resources

  • MEASUREMENT_SUBMITMEASUREMENT_REUSE_NOT_ALLOWED: Reuse of resource with id %s is not allowed.

  • MEASUREMENT_SUBMITMEASUREMENT_ASSOCIATED_QUALITY_NOT_PRESENT: Associated quality %s is not present on submitted resource. Reuse of resource is not allowed.

  • MEASUREMENT_SUBMITMEASUREMENT_QUALITY_IS_NOT_SUBSUMED: Quality %s does not subsume %s. Reuse of resource is not allowed.

  • MEASUREMENT_SUBMITMEASUREMENT_RESOURCE_TO_OLD_TO_BE_USED_FOR_REUSE: Reuse of resource is not allowed due to the resource being too old.

  • MEASUREMENT_SUBMITMEASUREMENT_DURATION_UNIT_CODE_UNKNOWN: Unsupported code %s for Duration.code. Duration.code should be a valid UCUM code. Supported codes are ('s', 'min', 'h', 'd', 'wk', 'mo', 'a').

  • MEASUREMENT_SUBMITMEASUREMENT_MORE_THAN_ONE_DEVICE_QUALITY: Only one device quality allowed for each observation/media

  • MEASUREMENT_SUBMITMEASUREMENT_INVALID_RESOLVED_TIMING: ResolvedTiming must have either type=Resolved and start/end or type=Unresolved/Adhoc/Extra and no start/end

  • MEASUREMENT_SUBMITMEASUREMENT_TOO_MANY_ANSWERS: QuestionnaireResponse: %s has too many answers for the item with linkId: %s

  • MEASUREMENT_SUBMITMEASUREMENT_TOO_FEW_ANSWERS: QuestionnaireResponse: %s has too few answers for the item with linkId: %s

  • MEASUREMENT_GET_DATA_NO_DATA_FOUND: Encrypted media data with id %s was not found

ehealth-observation

  • OBSERVATION_MEDIA_NOT_SUPPORTED_MESSAGE: Measurement was of media type. This was not translated to an observation since it is not supported in FHIR

ehealth-organization

  • ORGANIZATION_SOURCE_MUST_BE_MANUAL: The operation can only be performed for Organization with source "manual"

  • ORGANIZATION_IDENTIFIER_MUST_BE_SSL_WHEN_SOURCE_MANUAL: The operation can only be performed for SSL Organizations when the source is "manual"

  • ORGANIZATION_IDENTIFIER_NOT_UNIQUE: Organization Identifier not unique: %s

  • ORGANIZATION_IDENTIFIER_SYSTEM_NOT_ALLOWED_FOR_SOURCE_MANUAL: Identifier system is not allowed for Organization with source "manual"

  • ORGANIZATION_TRAVERSE_TO_SOR_NOT_POSSIBLE: No related SOR organization could be found for: %s

  • ORGANIZATION_IDENTIFIER_MUST_CONTAIN_AT_LEAST_CVR_FOR_SOURCE_MANUAL: Identifier system CVR required for Organization with source "manual"

  • ORGANIZATION_UNKNOWN_IDENTIFIER: Unable to find unique Organization with identifier: %s. Number of search results: %s

  • ORGANIZATION_MISSING_IDENTIFIER: Organization %s does not have identifier of type: %s

ehealth-plandefinition

  • PLANDEFINITION_UPDATE_ALLOWED_FOR_STATUS: Update is only allowed for PlanDefinition with status: %s or %s.

  • PLANDEFINITION_UPDATE_TO_NOT_ALLOWED_STATE: Update is not allowed for PlanDefinition with %s status to different than %s status.

  • PLANDEFINITION_VALIDATE_MANDATORY_ACTIVITYDEFINITION_OR_SUBPLAN_REFERENCE: At least one activity definition or subplan should be referenced.

  • PLANDEFINITION_VALIDATE_ALL_REFERENCED_ACTIVITYDEFINITIONS_OR_SUBPLANS_SHOULD_BE_ACTIVE: All referenced activity definitions or subplans should be with state: "active"

  • PLANDEFINITION_MISSING_RELATED_ACTION: An action points to a non-existing related action

ehealth-provenance

  • PROVENANCE_NO_READ_PRIVILEGE: User must be logged in with the provenance read privilege

  • PROVENANCE_NO_SEARCH_PRIVILEGE: User must be logged in with the provenance search privilege

  • PROVENANCE_SEARCH_DATA_NOT_MATCH_CONTEXT: The target property should match to the episode of care in context

ehealth-qfdd

  • QFDD_NARRATIVE_MISSING_TEXT_ERROR: Information section does not have a text element. LinkId: %s

  • QFDD_NARRATIVE_MISSING_EXTENSION_ERROR: Information section does not have a rendering-xhtml extension. LinkId: %s

ehealth-questionnaire

  • QUESTIONNAIRE_NOT_ALLOWED_TO_UPDATE_IN_STATUS: Update is not allowed for questionnaires with statuses: %s, %s

  • QUESTIONNAIRE_NOT_ALLOWED_TO_UPDATE_STATUS: Update is not allowed for questionnaires with %s status to different than %s status

  • QUESTIONNAIRE_NOT_ALLOWED_TO_DELETE_WITH_STATUS: Delete only possible for questionnaires with status: %s

  • QUESTIONNAIRE_IMAGE_FORMAT_VALIDATION_MESSAGE: %s Image in questionnaire item with linkID %s and Binary contentType %s does not match any code in ValueSet: %s

  • QUESTIONNAIRE_IMAGE_SIZE_VALIDATION_MESSAGE: %s Image in questionnaire item with linkID %s exceeds the maximum size of %s kB

  • QUESTIONNAIRE_QFDD_DOES_NOT_EXIST_IN_DOCUMENT_TRANSFORMATION: The QFDD with the identifier %s does not exist in document transformation

  • QUESTIONNAIRE_TERMINOLOGY_HELPER_CODE_NOT_FOUND: Code %s for CodeSystem %s not found

  • QUESTIONNAIRE_TERMINOLOGY_HELPER_CODE_SYSTEM_NOT_FOUND: Code system not found for url: %s

  • QUESTIONNAIRE_TERMINOLOGY_HELPER_CODE_SYSTEM_FOUND_MORE_THAN_ONE: Found more than one code system for url: %s

ehealth-reporting

  • REPORTING_MISSING_INPUT_PARAMETER: Parameter "%s" is mandatory for report "%s".

  • REPORTING_REPORT_GENERATION_FAILED: Report generation has failed

  • REPORTING_SYNCHRONOUS_GENERATION_NOT_ALLOWED: Synchronous generation of the report is not allowed

  • REPORTING_SCHEDULE_NOT_ALLOWED: Scheduled generation of the report is not allowed

  • REPORTING_EXECUTE_NOT_ALLOWED: Asynchronous generation of the report is not allowed

  • REPORTING_MUTUALLY_EXCLUSIVE_INPUT_PARAMETER: Parameters "%s" and "%s" are mutually exclusive for report "%s".

ehealth-security

  • SECURITY_TOKEN_CONTEXT_NOT_ALLOWED: Security token context not allowed: %s

  • SECURITY_TOKEN_INSUFFICIENT_PERMISSION: Insufficient permission for %s for %s

  • SECURITY_USER_NOT_ALLOWED: Resource not allowed for user: %s

  • SECURITY_TOKEN_CONTEXT_MISSING: Security token context missing for user type: %s

  • SECURITY_TOKEN_CONTEXT_MISSING_CONTEXT: Security token context missing for context type: %s

  • SECURITY_RESOURCE_NOT_MATCHING_TOKEN_CONTEXT: Resource not matching security token context: %s

  • SECURITY_OPERATION_NOT_ALLOWED_FOR_USER_TYPE: Operation not allowed for user type: %s

  • SECURITY_SEARCH_PARAM_NOT_MATCHING_TOKEN_CONTEXT: Search parameters not matching security token context: %s

  • SECURITY_SEARCH_PARAMS_MANDATORY: Search parameters mandatory with current user type and combination of search parameters: %s

  • SECURITY_SEARCH_OPERATION_POST_CONSTRAINT: Search on %s only supports POST style.

ehealth-status

  • STATUS_SCHEDULE_PAUSE_MAX_30_DAYS: A scheduled pause may not last more than 30 days

  • STATUS_SCHEDULE_IDENTICAL_TIME: Multiple status changes may not be scheduled to be activated simultaneously

ehealth-system

  • SYSTEM_TAG_UNEXPECTED_TAG: Resource contains system tag(s), which do not match related resource.

ehealth-task

  • TASK_INVESTIGATION_ITEM_REFERENCES_MUST_HAVE_VERSION_AND_VERSIONLESS: Investigation references must have an item with version and one versionless

  • TASK_RESTRICTION_CATEGORY_NONE_CANT_BE_COMBINED: Restriction category 'None' can't be combined with others

  • TASK_RESTRICTION_CATEGORY_NOT_MATCHING_TOKEN_CONTEXT: Restriction category '%s' does not match token context

  • TASK_MEASUREMENT_PROCESSING_FAILED: Measurement processing failed for Provenance %s

  • TASK_AUTOMATED_PROCESSING_RESOURCE_HANDLER_INVALID_JSON: Unable to parse json string: %s.

  • TASK_AUTOMATED_PROCESSING_INVALID_INPUT_RESOURCE: Resource of type %s is not a valid input resource.

  • TASK_AUTOMATED_PROCESSING_MISSING_MEASUREMENT_PROCEDURE_REQUEST: Could not determine if measurement is missing for procedure request: %s.

  • TASK_AUTOMATED_PROCESSING_FAILING_REQUESTS_JOB_TERMINATED: Limit of %s consecutive failing requests is reached. Scheduled audit job is terminated.

  • TASK_AUTOMATED_PROCESSING_CAREPLAN_NOT_FOUND: CarePlan is not found when searching by activity: %s.

  • TASK_AUTOMATED_PROCESSING_RULE_OUTPUT_NOT_FOUND: RuleOutput not found when searching through Task Automated Processing Resource

  • TASK_FOR_NOT_SET: When episode of care is set, the field 'for' must reference the corresponding patient

ehealth-transformation

  • TRANSFORMATION_DEPRECATE_DOCUMENT_CPR_DIDNT_MATCH: Found document didn't match with CPR

  • TRANSFORMATION_DEPRECATE_DOCUMENT_MORE_THAN_ONE_FOUND: More than 1 DocumentReference with same master identifier found. The master identifier should be unique.

  • TRANSFORMATION_DEPRECATE_DOCUMENT_NO_DOCUMENT_FOUND: No matching document found

  • TRANSFORMATION_QFDD_UNKNOWN_QUESTION_TYPE: Unknown QFDD question type. Question id: %s

  • TRANSFORMATION_QFDD_UNSUPPORTED_STRUCTURE: The root item structure was neither an Information Only Section nor a Question Section. LinkId: %s

  • TRANSFORMATION_QFDD_XML_MISSING: Invalid input document reference, it must contain content with data of QFDD xml

  • TRANSFORMATION_QFDD_ITEM_WITH_SLIDER_MISSING_STEPVALUE: Questionnaire item with linkId '%s' has itemControl: 'slider' but has no step value extension.

  • TRANSFORMATION_QFDD_ITEM_WITH_SLIDER_NOT_MATCHING_DISCRETE_SLIDER: Questionnaire item with linkId '%s' has itemControl: 'slider' but either repeats if true. Was: %s. or maxOccursValue is larger than 1. Was: %s.

  • TRANSFORMATION_QFDD_CODESYSTEM_TITLE_MISSING: CodeSystem title is missing, for CodeSystem with url: %s

  • TRANSFORMATION_QFDD_QUESTION_NARRATIVE_FILE_TEMPLATE_ERROR: Template for question section narrative can't be found or written.

  • TRANSFORMATION_QFDD_QUESTION_NARRATIVE_TEMPLATE_SYNTAX_ERROR: Could not process template for question section narrative due to syntax errors or missing variables

  • TRANSFORMATION_QRD_INVALID_INPUT_PARAMETERS: Input bundle should contain just one EHealthComposition, EHealthQuestionnaireResponse, EHealthQuestionnaire and DocumentReference(QFDD).

  • TRANSFORMATION_FROM_QRD_INVALID_INPUT_PARAMETERS: Input bundle should contain just one EHealthQuestionnaire and DocumentReference(QRD).

  • TRANSFORMATION_FROM_QRD_DUPLICATED_EXTERNAL_IDENTIFIER: Cannot transform from QRD to QuestionnaireResponse. Duplicated external identifiers: %s.

  • TRANSFORMATION_FROM_QRD_EXTERNAL_DOCUMENT_NOT_MATCHING_QFDD_IDENTIFIER_ON_QUESTIONNAIRE: External Document reference in QRD does not match QFDD identifier on Questionnaire. External Document reference: '%s'. QFDD identifier on Questionnaire: '%s'.

  • TRANSFORMATION_FROM_QRD_NO_EXTERNAL_DOCUMENT_FOUND_IN_QRD: No External Document reference found in QRD.

  • TRANSFORMATION_FROM_QRD_NO_QFDD_IDENTIFIER_ON_QUESTIONNAIRE: Questionnaire does not have a QFDD identifier. No identifier with system starting with 'urn:oid'.

  • TRANSFORMATION_FROM_QRD_COULD_NOT_FIND_PARENT_FOR_LINK_ID: Could not find parent for item with linkId: %s.

  • TRANSFORMATION_FROM_QRD_QRD_HAS_NO_SECTIONS: QRD has no sections with questions.

  • TRANSFORMATION_FROM_QRD_QRD_QUESTION_TYPE_DOES_NOT_MATCH_QUESTIONNAIRE_ITEM_TYPE: QRD Question type '%s' does not match questionnaire item type '%s'. LinkId: %s.

  • TRANSFORMATION_QRD_UNSUPPORTED_QUESTION_TYPE: Unsupported Questionnaire type: %s.

  • TRANSFORMATION_QRD_INVALID_NUMBER_OF_ANSWERS: QuestionnaireResponse item should contain from %s to %s answers.

  • TRANSFORMATION_QRD_SLIDER_MISMATCH_BETWEEN_TYPE_AND_SLIDER_STEP: Questionnaire item with linkId '%s' has itemControl: 'slider' and item.type: 'Integer' but has decimal step value: %s.

  • TRANSFORMATION_QRD_INVALID_SLIDER_EXTENSIONS: Questionnaire item with linkId '%s' has itemControl: 'slider', therefore it must contain at least the following extensions: %s.

  • TRANSFORMATION_QRD_NO_SLIDER_STEP_EXTENSION: Questionnaire item with linkId '%s' has itemControl: 'slider', therefore it must contain one of the following extensions: %s.

  • TRANSFORMATION_QRD_NO_SLIDER_ITEM_CONTROL_EXTENSION: Questionnaire item with linkId '%s' has no itemControl extension with code: 'slider'.

  • TRANSFORMATION_QRD_MISSING_IDENTIFIER: Identifier on composition is mandatory

  • TRANSFORMATION_QRD_XML_MISSING: Invalid input document reference, it must contain content with data of QRD xml

  • TRANSFORMATION_QRD_EXPECTING_DISPLAY_ITEM_FOR_INFO_SECTION: QFDD section with title '%s' has no organizers(Information Only Section). Expecting FHIR Questionnaire root group to have exactly one item of display. Found %s items.

  • TRANSFORMATION_QRD_EXPECTING_DISPLAY_ITEM_FOR_INFO_SECTION_FOUND_OTHER_TYPE: QFDD section with title '%s' has no organizers(Information Only Section). Expecting FHIR Questionnaire root group to contain exactly one item of type 'display'. Found item of type: '%s'.

  • TRANSFORMATION_QRD_NUMBER_OF_ITEMS_IN_ROOT_GROUP_DOES_NOT_MATCH_NUMBER_OF_ORGANIZERS: QFDD section with title '%s' has %s organizers. Expect FHIR Questionnaire root group to contain the same number of items with type 'group'. Found: %s.

  • TRANSFORMATION_QRD_EXPECTING_ONLY_SUB_GROUPS_IN_ROOT_GROUP: QFDD section with title '%s' has %s organizers. Expect FHIR Questionnaire root group to contain only items of type: 'group'.

  • TRANSFORMATION_QRD_EXPECTING_ROOT_ITEM_TO_BE_OF_TYPE_GROUP: Root item on questionnaire is not of type 'group'. Type was: %s

  • TRANSFORMATION_QRD_EXPECTING_ITEM_TO_BE_OF_TYPE_GROUP: Item is not of type group. Type: %s

  • TRANSFORMATION_QRD_NUMBER_OF_ITEMS_ON_ROOT_LEVEL_DOES_NOT_MATCH_NUMBER_OF_SECTIONS: The number of root items on questionnaire does not match the number of QFDD sections. Questionnaire: %s.

  • TRANSFORMATION_QRD_FOUND_MORE_THAN_ONE_MATCH_FOR_LINKID_IN_QUESTIONNAIRE_RESPONSE: Found more than 1 match for LinkId in QuestionnaireResponse. LinkId: %s.

  • TRANSFORMATION_QRD_NO_MATCH_FOR_ASSOCIATED_TEXT_QUESTION_IN_QUESTIONNAIRE_RESPONSE: Found no match for associatedTextQuestion in QuestionnaireResponse. Found Questionnaire item with linkId: %s.

  • TRANSFORMATION_QRD_EXPECTING_QUESTIONNAIRE_TIEM_TO_HAVE_EXTERNAL_IDENTIFIER: Expected questionnaireItem to have externalIdentifier: %s. But was: %s

  • TRANSFORMATION_QRD_FOUND_NO_QUESTIONNAIRE_RESPONSE_FOR_ASSOCIATED_TEST_QUESTION: Found no QuestionnaireResponse for associatedTextQuestion. Found Questionnaire item with linkId: %s.

  • TRANSFORMATION_QRD_PRECONDITION_DO_NOT_MATCH_THE_QUESTION_FOR_ASSOCIATED_TEXT_QUESTION: The precondition criterion code does not match the expected question code. Expected: %s. But was: %s

  • TRANSFORMATION_QRD_MULTIPLE_CHOICE_ANSWER_EXPECTING_CODING_TYPE_FOR_VALUE: Expecting answer value to be of type Coding. QuestionResponseItem with linkId: %s.

  • TRANSFORMATION_QRD_PRECONDITION_GROUP_GROUP_TYPE_UNKNOWN: Unknown GroupType: %s

  • TRANSFORMATION_QRD_PRECONDITION_MORE_THAN_ONE: Transformation do not support more than one precondition for associatedTextQuestion. Found %s. AssociatedTextQuestion: %s

  • TRANSFORMATION_QRD_EXPECT_IMAGE_IN_QUESTIONNAIRE_ITEM: Expecting QuestionnaireItem to have an image as the corresponding QFDD question has an image. Question id: %s

  • TRANSFORMATION_QRD_NOT_EXPECTING_IMAGE_IN_QUESTIONNAIRE_ITEM: Not expecting QuestionnaireItem to have an image as the corresponding QFDD question do not have an image. Question id: %s

  • TRANSFORMATION_QRD_UNKNOWN_QRD_RESPONSE_TYPE: Unknown QRD response type. QRD Question id: %s

  • TRANSFORMATION_QRD_ASSOCIATED_TEXT_QUESTION_ITEM_NOT_OF_TYPE_TEXT: AssociatedTextQuestion item with id: '%s' is not of type 'text'. Type was: %s

  • TRANSFORMATION_QRD_QFDD_QUESTION_DOES_NOT_SUPPORT_ASSOCIATED_TEXT_QUESTION: QFDDQuestion with id: '%s' does not support associatedText. Class was: %s

  • TRANSFORMATION_PHMR_MISSING_RESOURCE: Input bundle missing resource: %s

  • TRANSFORMATION_PHMR_NARRATIVE_ERROR: Can't generate narrative for: %s

  • TRANSFORMATION_HEADER_MISSING_CPR: CPR is mandatory for patient but not present in fhir bundle

  • TRANSFORMATION_PHMR_INVALID_OBSERVATION_CODING: Observation coding system must be urn:oid:1.2.208.176.2.1

  • TRANSFORMATION_PHMR_INVALID_OBSERVATION_COMMENT_AUTHOR_REFERENCE: The author of a measurement comment is a reference not provided in the bundle.

  • TRANSFORMATION_PHMR_INVALID_OBSERVATION_RANGES_CODING: Observation.observationRanges[x].type.coding.system should be http://www.example.com/medcom/message-codes

  • TRANSFORMATION_PHMR_INVALID_OBSERVATION_RANGES_RAL: RAL observation ranges should not have both High and Low set when transforming to PHRM, but High is: %s, and Low is: %s

  • TRANSFORMATION_PHMR_INVALID_OBSERVATION_RANGES_GAL: GAL observation ranges should not have both High and Low set when transforming to PHRM, unless either bound is replaced with a RAL reference range, but High is: %s, and Low is: %s

  • TRANSFORMATION_PHMR_INVALID_NUMBER_OF_DECIMALS: Value should have no more than 7 decimals, but is: %s

  • TRANSFORMATION_PHMR_OBSERVATION_QUANTITY_MISSING: Value should be Quantity type and not null

  • TRANSFORMATION_PHMR_XML_MISSING: Invalid input document reference, it must contain content with data of PHMR xml

  • TRANSFORMATION_PHMR_ID_OID_NOT_FOUND: NamingSystem or CodeSystem with url %s is not found.

  • TRANSFORMATION_PHMR_MISSING_MEASUREMENT_IDENTIFIER: No identifier found for measurement

  • TRANSFORMATION_PHMR_DOCUMENT_TIME_INTERVAL_MISSING: Document is missing serviceStartTime and serviceStopTime.

  • TRANSFORMATION_PHMR_DOCUMENT_INVALID_EFFECTIVE: Invalid Observation.effective, expecting DateTime, Period or Instant

  • TRANSFORMATION_PHMR_MEASUREMENT_INVALID_METHOD_CODES: Method codes for performerType and provisionMethod for observation with id '%s' could not be established.

  • TRANSFORMATION_PHMR_MEASUREMENT_TOO_MANY_DECIMALS: Could not transform measurement with reference range Low: %s and High: %s since we cannot correctly translate more than 7 decimals.

  • TRANSFORMATION_HEADER_MISSING_CONFIDENTIALITY_CODE: Composition.confidentiality is mandatory

  • TRANSFORMATION_HEADER_WRONG_TYPE_COMPOSITION_SUBJECT: Composition.subject should be a Patient

  • TRANSFORMATION_HEADER_MISSING_CUSTODIAN: Custodian is mandatory for transformation

  • TRANSFORMATION_HEADER_MISSING_COMPOSITION: Composition expected for transformation is not found

  • TRANSFORMATION_HEADER_MISSING_ATTESTER: Composition.attester.party is mandatory for transformation

  • TRANSFORMATION_HEADER_WRONG_TYPE_COMPOSITION_AUTHOR: Composition.author should either be a Patient or Practitioner

  • TRANSFORMATION_HEADER_MISSING_COMPOSITION_AUTHOR_ORGANIZATION: Composition.authorOrganization is mandatory for transformation

  • TRANSFORMATION_HEADER_AUTHOR_ORGANIZATION_MUST_CONTAIN_SOR_ID: Composition.authorOrganization must contain SOR identifier: %s

  • TRANSFORMATION_HEADER_ATTESTER_ORGANIZATION_MUST_CONTAIN_SOR_ID: Composition.attester.party must contain SOR identifier: %s

  • TRANSFORMATION_HEADER_CUSTODIAN_MUST_CONTAIN_SOR_ID: Custodian organization must contain SOR identifier: %s

  • TRANSFORMATION_HEADER_COMPOSITION_HAS_NO_TIMEZONE_OR_SECONDS: Composition has no timezone or seconds set: %s

  • TRANSFORMATION_XDS_PROPERTY_MISSING_EXCEPTION: '%s' is missing which is required for document sharing. DocumentReference id: '%s'.

  • TRANSFORMATION_XDS_PROPERTY_CODE_INVALID_EXCEPTION: '%s' is required for document sharing but the specified coding is not valid for the valueSet '%s': system=%s, code=%s, display=%s. DocumentReference id: '%s'

  • TRANSFORMATION_FROM_XHTML_TO_CDA_XML_FAILED: Unable to transform XHTML to CDA XML format

  • TRANSFORMATION_FROM_CDA_XML_TO_XHTML_FAILED: Unable to tranform CDA XML to XHTML format

  • TRANSFORMATION_XSLT_CONFIGURATION_ERROR: Error creating XLST transformer: %s

  • TRANSFORMATION_XSD_CONFIGURATION_ERROR: Error creating XSD transformer: %s

  • TRANSFORMATION_APD_XML_MISSING: Invalid input document reference, it must contain content with data of APD xml

ehealth-upload

  • UPLOAD_QFDD_MASTERIDENTIFIER_IS_ALREADY_IN_USE: The masterIdentifier on the DocumentReference is not unique

  • UPLOAD_QFDD_THE_ID_OF_THE_DOCUMENT_IS_NULL: Missing Id in the QFDD.

ehealth-versioning

  • VERSIONING_RESOURCE_MUST_BE_FROM_CURRENT_ENVIRONMENT: Versioning validation error: Resource must be from current environment: %s.

  • VERSIONING_MULTIPLE_DRAFTS_IN_BASE_NOT_ALLOWED: Versioning validation error: Only one draft resource at a time is allowed per base.

  • VERSIONING_RESOURCE_NOT_ELIGIBLE_FOR_CLONE: Versioning validation error: A resource must have base-identifier, environment-identifier, versioning-identifier and version to be cloned.

  • VERSIONING_REFERENCE_NOT_RELEVANT_FOR_RESOURCE: Versioning validation error: References included in deep_clone_references must be present in resource to clone, %s: %s.

  • VERSIONING_REFERENCE_MISSING_IN_TREE_PATH: Versioning validation error: The following resources could not be cloned since their parent resource, %s, is not present in deep_clone_refernces: %s.

ehealth-message

  • COMMUNICATION_EXACTLY_ONE_RECIPIENT_OR_CARE_TEAM_RECIPIENT_MUST_BE_SUPPLIED: Exactly one recipient or CareTeam recipient must be supplied

  • COMMUNICATION_EXACTLY_ONE_SENDER_OR_CARE_TEAM_SENDER_MUST_BE_SUPPLIED: Exactly one sender or CareTeam sender must be supplied

  • COMMUNICATION_UPDATE_TO_CATEGORY_IS_NOT_ALLOWED: Update to category is not allowed: %s

  • COMMUNICATION_ONLY_STATUS_COMPLETED_CAN_HAVE_ADMINISTRATIVE_STATUS_OTHER_THAN_ACTIVATE: Only Communication with status 'COMPLETED' can have an administrative-status other than 'activate'

  • COMMUNICATION_ONLY_STATUS_COMPLETED_CAN_BE_MARKED_AS_RECEIVED: Only Communication with status 'COMPLETED' can have a 'received' timestamp

  • COMMUNICATION_SENT_PROP_CANNOT_BE_SET_BY_CLIENT: Communication 'sent' property is managed by the server and cannot be set by the client

  • COMMUNICATION_ONLY_ADMINISTRATIVE_STATUS_AND_RECEIVED_CAN_BE_UPDATED_WHEN_STATUS_IS_COMPLETED: Only administrative-status extension and 'received' propery can be updated when status is 'COMPLETED'

  • COMMUNICATION_JSON_PATCH_IS_ONLY_ALLOWED_FOR_NOTE: This JSON patch type is only allowed for category '%s' (current is '%s')

  • COMMUNICATION_EXACTLY_ONE_MESSAGE_CATEGORY_IS_EXPECTED_ACTUAL: Exactly one message category is expected. Actual: %s

  • COMMUNICATION_MEDIUM_EBOKS_OR_NEMSMS_REQUIRES_PATIENT_RECIPIENT: A recipient of type Patient is required for this medium: %s

  • COMMUNICATION_PATIENT_NEMSMS_NOT_ALLOWED: Patient does not allow telecom medium NemSMS

  • COMMUNICATION_EXACTLY_ONE_CAREPLAN_MUST_BE_SUPPLIED_WHEN_REASON_CODE_MISSING_MEASUREMENT_RESOLVING: A message must be part of exaclty one CarePlan when reasonCode 'missing-measurment-resolving' is set

  • COMMUNICATION_STATUS_COMPLETED_OR_STOPPED_CANNOT_BE_SET_BY_CLIENT: Communication with status 'COMPLETED' or 'STOPPED' are reserved for system use and cannot be set directly by the client

  • COMMUNICATION_WITH_STATUS_INPROGRESS_OR_STOPPED_CANNOT_BE_UPDATED_BY_CLIENT: Communication with status 'INPROGRESS' or 'STOPPED' cannot be updated by the client

  • COMMUNICATION_NEMSMS_WITH_STATUS_COMPLETED_CANNOT_BE_UPDATED_BY_CLIENT: Communication with medium 'nemsms' and status 'COMPLETED' cannot be updated by the client

ehealth-appointment, ehealth-group-appointment, ehealth-videoappointment and ehealth-group-videoappointment

  • APPOINTMENT_NOT_ALLOWED_TO_UPDATE_STATUS_ONCE_THE_APPOINTMENT_HAS_ENTERED_CANCELLED_OR_ENTEREDINERROR: Status change not allowed

  • APPOINTMENT_NOT_ALLOWED_TO_CHANGE_SYSTEM_IDENTIFIER: Manipulation of system identifiers not allowed

  • APPOINTMENT_NOT_ALLOWED_TO_CHANGE_CREATOR: Manipulation of creator identifier not allowed

  • APPOINTMENT_NOT_ALLOWED_TO_CHANGE_VDX_IDENTIFIER: Manipulation of VDX identifiers not allowed

ehealth-patient, ehealth-relatedperson, ehealth-skrs-patient and Person

  • PATIENT_OFFICIAL_NAME_CHANGE_NOT_ALLOWED: Official name change not allowed

  • PATIENT_CPR_CHANGE_IS_NOT_ALLOWED: CPR change is not allowed

  • PATIENT_HOME_ADDRESS_CHANGE_IS_NOT_ALLOWED: Home address change is not allowed

  • PATIENT_ADDRESS_VALIDATION_FALIED: Patient address validation failed: %s

  • PATIENT_MUST_HAVE_CRN_IDENTIFIER: No CPR identifier found

  • PERSON_WITH_THAT_CPR_NUMBER_DOES_NOT_EXIST: Provided CPR number does not link to a person in the external CPR registry

  • PERSON_CPR_NUMBER_NOT_PROVIDED: No CPR Provided